title: "GEM® Premier™ 7000 hemolysis detection across HbA, HbS, and HbF in whole blood"
id: "pubmed-42900906"
canonical_url: "https://medichelpline.com/clinical-feed/pubmed-42900906"
content_type: "clinical_feed_article"
specialty: "Critical Care"
source_name: "PubMed / NCBI"
source_url: "https://pubmed.ncbi.nlm.nih.gov/42900906/"
doi: "10.1515/cclm-2026-1538"
published_at: "2026-10-22T00:00:00.000Z"
evidence_level: "Journal Article"
license: "CC-BY-NC-4.0 / Informational Use"
---
# GEM® Premier™ 7000 hemolysis detection across HbA, HbS, and HbF in whole blood
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/pubmed-42900906
- **Specialty:** [Critical Care](https://medichelpline.com/clinical-feed/critical-care.md)
- **Primary Source:** PubMed / NCBI
- **Source URL:** [Original Journal Publication](https://pubmed.ncbi.nlm.nih.gov/42900906/)
- **DOI:** [10.1515/cclm-2026-1538](https://doi.org/10.1515%2Fcclm-2026-1538)
- **Published At:** 2026-10-22T00:00:00.000Z
- **Evidence Rating:** Journal Article
## Executive GIST (TL;DR)
- The study evaluated the onboard hemolysis detection of the **GEM® Premier™ 7000** for whole blood, focusing on effects of hemolysis on measured **potassium** and detection across hemoglobin variants. - Investigators analyzed 50 patient arterial blood samples paired with Atellica Solution analyzers to assess analytical behavior during induced hemolysis. The report gives concrete pre- and post-hemolysis comparisons. - Experimental hemolysis drove median hemolysis index values from 1 to 6 and median potassium from 3.6 to 9.8 mmol/L; the change was statistically significant (p<0.001), the study team observed. - A second experiment used samples from 10 healthy volunteers with deliberate hemoglobin overload using **HbA0**, **HbS**, and **HbF** to probe variant-dependent detection performance. - Data indicated the onboard multi-wavelength co-oximetry method accurately tracked increasing free hemoglobin concentrations for all three hemoglobin types during overload experiments. - Authors concluded the integrated hemolysis detection reliably flagged clinically significant hemolysis in whole blood, supporting improved point-of-care blood gas result interpretation. - The abstract did not report detailed assay limits of detection, specific hemoglobin concentration thresholds, full statistical tables, or precise methodological parameters for the overload protocol; those details were not provided in the source.
## Clinical Analysis & Structured Key Points
Whole blood hemolysis detection on the GEM® Premier™ 7000: performance across hemoglobin A, S, and F - PubMed This site needs JavaScript to work properly. Please enable it to take advantage of the complete set of features! Clipboard, Search History, and several other advanced features are temporarily unavailable. Skip to main page content The .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site. The site is secure. The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely. Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation Search: Search Advanced Clipboard User Guide Save Email Send to Clipboard My Bibliography Collections Citation manager Display options Display options Format Abstract PubMed PMID Save citation to file Format: Summary (text) PubMed PMID Abstract (text) CSV Create file Cancel Email citation Email address has not been verified. Go to My NCBI account settings to confirm your email and then refresh this page. To: Subject: Body: Format: Summary Summary (text) Abstract Abstract (text) MeSH and other data Send email Cancel Add to Collections Create a new collection Add to an existing collection Name your collection: Name must be less than 100 characters Choose a collection: Unable to load your collection due to an error Please try again Add Cancel Add to My Bibliography My Bibliography Unable to load your delegates due to an error Please try again Add Cancel Your saved search Name of saved search: Search terms: Test search terms Would you like email updates of new search results? Saved Search Alert Radio Buttons Yes No Email: ( change ) Frequency: Monthly Weekly Daily Which day? The first Sunday The first Monday The first Tuesday The first Wednesday The first Thursday The first Friday The first Saturday The first day The first weekday Which day? Sunday Monday Tuesday Wednesday Thursday Friday Saturday Report format: Summary Summary (text) Abstract Abstract (text) PubMed Send at most: 1 item 5 items 10 items 20 items 50 items 100 items 200 items Send even when there aren't any new results Optional text in email: Save Cancel Create a file for external citation management software Create file Cancel Your RSS Feed Name of RSS Feed: Number of items displayed: 5 10 15 20 50 100 Create RSS Cancel RSS Link Copy Full text links De Gruyter Full text links Actions Cite Collections Add to Collections Create a new collection Add to an existing collection Name your collection: Name must be less than 100 characters Choose a collection: Unable to load your collection due to an error Please try again Add Cancel Permalink Permalink Copy Display options Display options Format Abstract PubMed PMID Experimental Resource Linked Discoveries Full text links Cite Display options Display options Format Abstract PubMed PMID Linked Discoveries Abstract Objectives: Point-of-care blood gas analyzers are essential in critical care settings but remain vulnerable to pre-analytical interferences, particularly hemolysis, which may lead to erroneous potassium results. The GEM ® Premier™ 7000 incorporates an onboard hemolysis detection system based on multi-wavelength co-oximetry, allowing direct estimation of free hemoglobin in whole blood samples. This study evaluated the analytical performance of this system across different hemoglobin variants, including fetal hemoglobin (HbF) and hemoglobin S (HbS). Methods: Fifty patient samples undergoing routine arterial blood gas and biochemical testing were analyzed using the GEM ® Premier™ 7000, and Atellica Solution analyzers. Experimental hemolysis was induced to evaluate the performance of the onboard hemolysis detection system. In a second step, hemoglobin overload experiments using HbA 0 , HbF, and HbS were performed in samples from 10 healthy volunteers to assess the robustness of hemolysis detection across different hemoglobin variants. Results: Experimental hemolysis significantly increased the hemolysis index and potassium concentrations measured on the GEM ® Premier™ 7000, with median hemolysis index values rising from 1 to 6 and median potassium concentrations from 3.6 to 9.8 mmol/L (p<0.001). The GEM ® Premier™ 7000 accurately detected increasing concentrations of free HbA 0 , HbS, and HbF throughout the overload experiments. Conclusions: The integrated hemolysis detection system reliably detected clinically significant hemolysis in whole blood samples, supporting more reliable point-of-care blood gas testing. Keywords: hemolysis; point-of-care testing; potassium; whole blood. © 2026 Walter de Gruyter GmbH, Berlin/Boston. PubMed Disclaimer References St John, A, Price, CP. Existing and emerging technologies for point-of-care testing. Clin Biochem Rev 2014;35:155–67. Price, CP. Point of care testing. BMJ 2001;322:1285–8. https://doi.org/10.1136/bmj.322.7297.1285 . - DOI Dukić, L, Kopčinović, LM, Dorotić, A, Baršić, I. Blood gas testing and related measurements: national recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochem Med 2016;26:318–36. https://doi.org/10.11613/BM.2016.036 . - DOI Plebani, M. Errors in laboratory medicine and patient safety: the road ahead. Clin Chem Lab Med 2007;45:700–7. https://doi.org/10.1515/CCLM.2007.170 . - DOI Lippi, G, Chance, JJ, Church, S, Dazzi, P, Fontana, R, Giavarina, D, et al.. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med 2011;49:1113–26. https://doi.org/10.1515/CCLM.2011.600 . - DOI Show all 27 references LinkOut - more resources Full Text Sources De Gruyter Research Materials NCI CPTC Antibody Characterization Program Miscellaneous NCI CPTAC Assay Portal Full text links [x] De Gruyter [x] Cite Copy Download .nbib .nbib Format: AMA APA MLA NLM Send To Clipboard Email Save My Bibliography Collections Citation Manager [x] NCBI Literature Resources MeSH PMC Bookshelf Disclaimer The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). Unauthorized use of these marks is strictly prohibited.
## Related Clinical Research

- [Postoperative delirium meta-analyses: a method to test sensitivity to assessment timing and freque](https://medichelpline.com/clinical-feed/plos-one-5-assessing-the-robustness-of-meta-analyses-to-variability-in-the-frequency-and.md)
- [Preparing Hospitals for Water Shortages: A Critical Analysis](https://medichelpline.com/clinical-feed/bmj-5-water-shortages-how-can-hospitals-prepare-and-are-water-companies-doing-enough.md)
- [β‑Caryophyllene (CB2 agonist) reduces lung inflammation after 5/6 nephrectomy in mice](https://medichelpline.com/clinical-feed/pubmed-42732653.md) (DOI: 10.1016/j.bbrc.2026.154579)
- [PIEZO1–YAP/TEAD Signaling Associates with POSTN-Enriched Fibroblast Activation in IPF](https://medichelpline.com/clinical-feed/pubmed-42727476.md) (DOI: 10.1016/j.bbrc.2026.154515)
- [Clinicians’ Views on “Fighting the Ventilator”: Survey of ICU Practice and Gaps](https://medichelpline.com/clinical-feed/medrxiv-23-clinicians-perspectives-on-fighting-the-ventilator.md)

## Navigation
- [← Back to Critical Care Feed](https://medichelpline.com/clinical-feed/critical-care.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.