---
title: "Reliability of Semi‑Automatic CBCT Segmentation for Condylar Hyperplasia Volume Assessment"
id: "plos-one-12-assessing-condylar-hyperplasia-management-outcomes-using-semi-automatic"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-12-assessing-condylar-hyperplasia-management-outcomes-using-semi-automatic"
content_type: "clinical_feed_article"
specialty: "Dentistry"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363132"
published_at: "2026-11-18T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Reliability of Semi‑Automatic CBCT Segmentation for Condylar Hyperplasia Volume Assessment
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-12-assessing-condylar-hyperplasia-management-outcomes-using-semi-automatic
- **Specialty:** [Dentistry](https://medichelpline.com/clinical-feed/dentistry.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363132)
- **Published At:** 2026-11-18T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- The investigators tested two semi-automatic segmentation landmarks to measure condylar volume on CBCT in patients with **Unilateral Condylar Hyperplasia (UCH)** who underwent **proportional condylectomy**. - Ten adult patients were randomly selected from a private surgical practice; CBCTs included affected and non-affected condyles, before and after surgery, yielding 20 condylar datasets. - Segmentation followed five steps: landmark identification, head orientation, mandibular segmentation, image refinement, and condyle unit segmentation using 3D Slicer and ITK‑Snap software. - Two anatomical cutting-plane methods were compared: the **sigmoid notch method (SN)** and the **mandibular lingula method (ML)**; a single blinded operator performed all measurements twice with a one‑month washout. - Intra-rater reliability was quantified with intraclass correlation coefficients (ICC) using a two‑way mixed‑effects model; random error was assessed by the Dahlberg formula. - Results indicated excellent intra-rater reliability for both methods: SN ICC = 0.96 (95% CI 0.92–0.98) and ML ICC = 0.91 (95% CI 0.79–0.96). - Method ML showed higher random measurement error and greater variability: average ML measurements were 9.9% higher on the second evaluation, versus 4.7% higher with SN. - The study team reported that semi-automatic condylar segmentation on **CBCT** is reproducible for volumetric assessment in complex mandibular condyles, with SN demonstrating slightly lower variability but ML remaining a viable clinical alternative. - The cohort size (n = 10 patients) and single-operator design, as reported in the source, limit generalizability and warrant further multi-operator validation and larger samples.
## Clinical Analysis & Structured Key Points
Assessing Condylar hyperplasia management outcomes using semi-automatic segmentation methods: A reliability study | PLOS One Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click here . Article Authors Metrics Comments Media Coverage Reader Comments Figures Figures Abstract Objectives To assess the reliability of two condylar segmentation methods in patients with Unilateral Condylar Hyperplasia (UCH) treated with proportional condylectomy. Methods A sample of 10 patients with UCH who underwent proportional condylectomy was randomly selected from a private practice. Landmarks were defined and volumetric measurements were performed from cone-beam computed tomography (CBCT) from affected (n = 10) and non-affected sides (n = 10), as well as before and after proportional condylectomy. Condyles were segmented using two methods: method SN (sigmoid notch method) and method ML (mandibular lingula method). A single blind operator performed the procedure twice, with a four-week interval between the evaluations. Random error was assessed using the Dahlberg formula, and intra-rater reliability was evaluated using the Intraclass correlation coefficient (ICC) in a two-way mixed-effects model. Results An excellent reliability was observed for both methods (SN: ICC = 0.96, CI 95% 0.92–0.98; ML: ICC = 0.91, CI 95%, 0.79–0.96). The method ML exhibited a slightly higher variability in measurement agreement, indicating higher random measurement error than method SN. On average, measurements with method ML were 9.9% higher on the second evaluation, while method SN measurements were 4.7% higher. Conclusions Condylar segmentation is a reliable approach for evaluating volumetric changes in complex mandibular condyles. While, both SN and ML segmentation methods demonstrated strong intra-rater reliability, the method SN exhibited slightly lower variability. Nonetheless, this study highlights the potential of method ML as a clinically relevant alternative to condylar assessment. Citation: Horta KC, Kharidehal N, Fagundes NCF, Pérez AP, Fariña R, Lagravère M, et al. (2026) Assessing Condylar hyperplasia management outcomes using semi-automatic segmentation methods: A reliability study. PLoS One 21(11): e0363132. https://doi.org/10.1371/journal.pone.0363132 Editor: Guoliang Sa, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School and Hospital of Stomatology, Wuhan University, CHINA Received: August 8, 2026; Accepted: November 4, 2026; Published: November 18, 2026 Copyright: © 2026 Horta et al. This is an open access article distributed under the terms of the Creative Commons Attribution License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: All data was submitted in the body of the manuscript and supplemental material. Funding: The author(s) received no specific funding for this work. Competing interests: The authors have declared that no competing interests exist. Introduction Mandibular condylar hyperplasia has an unknown etiology and is characterized by progressive, independent condylar growth, resulting in greater bone volume on one side than the other [ 1 , 2 ]. Prominent features include an enlarged mandibular condyle, elongated condylar neck, outward bowing, and downward growth of the body and ramus of the mandible on the affected side, causing fullness of the face on the ipsilateral side and flattening of the face on the contralateral side [ 3 ]. The excessive unilateral growth of the mandibular condyle may lead to occlusal disturbance and joint dysfunction [ 4 ]. A diagnosis of condylar hyperplasia can be supported by progressive lower facial asymmetry that develops during the pubertal growth spurt [ 5 , 6 ]. The objective measurement of asymmetry magnitude is essential for monitoring growth, guiding optimal timing of management, and assessing outcomes of surgical and non-surgical management. Several methods for measuring facial or mandibular asymmetry have been described in the literature [ 6 – 9 ]. However, the available literature lacks a clear description and reproducibility of possible landmarks and segmentation areas [ 10 ]. The measurement of asymmetry magnitude in Unilateral Condylar Hyperplasia (UCH) on panoramic radiographs has been previously performed, suggesting poor reproducibility and reliability of condylar neck and head measurements among these patients and limited screening value of this methodology for quantitative evaluation [ 11 ]. The use of three-dimensional (3D) assessment of the craniomaxillofacial and dentoalveolar structures using CBCT imaging [ 12 , 13 ]. However, 3D measurements of the mandibular condyle remain prone to segmentation errors due to the proximity of the glenoid fossa, the presence of connected soft tissues such as the articular disc, beam attenuation by the petrous part of the temporal bone, and its low inherent bone density [ 14 ]. Identifying a reliable landmark for volumetric condyle measurement would be significant for improving diagnosis and monitoring outcomes in patients with mandibular condylar hyperplasia. In this study, we aim to evaluate the reliability of two methods for assessing condylar volume in patients with UCH using CBCT scans. Materials and methods Ethics and sample characteristics This retrospective study received ethics approval from the University of Alberta (Pro00123198) and was conducted in accordance with the Declaration of Helsinki [ 15 ]. Given its design, all data were fully anonymized prior to investigator access, and the ethics committee waived the requirement for informed consent. CBCT Scans of ten randomly selected ( www.random.org ) patients were acquired from the private practice of one experienced oral-maxillofacial surgeon (RF) from Santiago, Chile. The data was accessed from 5/20/2025–15/03/2026. Adult individuals who were diagnosed with UCH, confirmed by clinical evaluation of progressive mandibular deviation with occlusal changes, as well as a cross-bite of the contralateral side or an ipsilateral open bite, and submitted to unilateral proportional condylectomy as the sole or initial surgical treatment were included in this study. Exclusion criteria comprised patients with facial asymmetry due to any cause other than UCH, and patients who underwent orthognathic surgery at the same time as condylectomy [ 16 ]. Data collection and volumetric measurements CBCT images of twenty condyles of patients with UCH who underwent proportional condylectomy were acquired. The samples consisted of affected and non-affected sides as well as before and after surgery scans of the condyles. The data obtained were anonymized, leaving only age at the CBCT scan and sex visible. Condylar volumetric changes of the ipsilateral and contralateral sides were assessed by following two methods and using two open-source software: 3D Slicer software, version 3.8 ( www.slicer.org ) [ 17 ] and ITK-Snap, version 3.8 ( www.itksnap.org ) [ 18 ]. After identifying the sample, anonymized CBCT files were exported to 3D Slicer software. All images underwent five steps to segment the condyle unit in the CBCT file: landmark identification, head orientation definition, mandibular segmentation, image refinement, and condyle unit segmentation ( Fig 1 ). A single blinded operator (NK) performed all measurements twice, with a one-month washout period [ 6 ]. Download: PNG larger image TIFF original image Fig 1. Steps for the condylar semi-automated volumetric measurements adopted in this study. https://doi.org/10.1371/journal.pone.0363132.g001 Landmark identification, head orientation and mandibular segmentation After exporting the CBCT file to the slicer software, thirteen 3D cephalometric landmarks were semi-automatically generated by using ALI CBCT (Automatic Landmark Identification in Cone-Beam Computed Tomography) [ 19 ] module: Sella (S), Basion (B), Nasion (N), right Porion (Po-r), left Porion (Po-l), right Orbitale (Or-r), left Orbitale (Or-l), right Condylion (Co-r), left Condylion (Co-l), right Sigmoid notch (Sig-r), left Sigmoid notch (Sig-l), right Lingula (Li-r), left Lingula (Li-l) [ 20 ]. The position of each landmark was manually refined wherever necessary. Once the final position of the landmarks was acquired, the 3D image was rendered by using the volume rendering module. The Transform module built into the software was then used to define the head orientation based on the Frankfort horizontal, midsagittal, and transporionic planes to match the axial, sagittal, and coronal planes. ( Fig 2 ). Download: PNG larger image TIFF original image Fig 2. 3D image volume rendered and Head Orientation of a representative case. After Head Orientation, the mandible was segmented using the AMASS module [ 21 ] ( Fig 3 ). https://doi.org/10.1371/journal.pone.0363132.g002 Imaging refinement The segmented file was exported to ITK-Snap software, and all the slices were reviewed individually to modify the prediction over- or under-segmentation as necessary. This step was repeated in all three views (i.e., axial, coronal, and sagittal) until an accurate, cohesive condylar unit was obtained, free of dead pixels or aberrant projections. The refined segmentation was moved back to 3D Slicer software and used with the Model Maker extension. Models of the mandible were created. Condyle unit segmentation Determining the lower boundary of the condylar unit is important, as the other boundaries are not in confluence with bone in the segmented Mandible.Two independent volumetric condyle measurements were performed using two methods and the module Easy Clip built into the 3D slicer software ( Fig 3 ). Download: PNG larger image TIFF original image Fig 3. A. Automatic segmentation of the mandible. B: Condylar segmentation by Method SN (superior image), and by Method ML (inferior image). https://doi.org/10.1371/journal.pone.0363132.g003 Method SN: The Sigmoid notch identifies the lowest point of the resected condylar segment, thereby defining its inferior limit. It also demarcates the most anterior extremity, establishing the anterior boundary, and serves as the most medial point in the mediolateral dimension, setting the medial boundary of the cut condyle. Method ML: Method ML takes the mandibular lingula as its key landmark. The lingula locates the lowest point of the resected condylar segment, establishing its inferior limit. It also pinpoints the most anterior extremity, fixing the anterior boundary, and serves as the most medial reference in the mediolateral dimension, defining the medial boundary of the cut condyle. Finally, the segmented condyles were transferred to ITK Snap for volumetric measurements. Data analysis To assess the reproducibility of the volume measurements, the random error and intra-rater reliability were assessed. The random error evaluation was measured using the Dahlberg formula, while overall reliability and systematic error evaluation were assessed through the Intraclass correlation coefficient (ICC), calculated in a two-way mixed-effects model. The level of agreement can be characterized as being excellent (≥0.9), good (0.75–0.89), moderate (0.5–0.74) or poor (<0.5). A trained orthodontist (NK) performed all volume measurements for both methods across the 20 condyles. To assess intra-examiner reliability (ICC), all measurements were performed twice with a four-week interval between the evaluations. The SPSS Statistical Package for the Social Sciences, version 26 (IBM, Armonk, NY) was used for data analysis. A p-value < 0.05 was considered to achieve statistical significance. Results The intraclass correlation coefficient showed excellent agreement level for both methods (ICC = 0.96 for method SN with a 95% Confidence Interval = 0.92–0.98; ICC = 0.91 for method ML with a 95% Confidence Interval = 0.79–0.96), and a detected random error of 38.33mm 3 and 220.18 mm 3 for SN and ML methods, respectively. The variability in the measurement agreement was higher for method ML. On average, method ML measurements were 9.9% higher when measured a second time, while measurements were 4.7% higher when measuring the method SN variable. Table 1 describes intra-examiner reliability, systematic and random error for both measurements. Download: PNG larger image TIFF original image Table 1. Intra-examiner reliability, systematic and random error. https://doi.org/10.1371/journal.pone.0363132.t001 Discussion This study aimed to investigate the reproducibility of two semi-automated segmentation methodologies based on CBCT imaging for assessing outcomes of condylar hyperplasia management. Although both methodologies are established in the literature, they differ regarding their reference landmarks and resulting measurement boundaries, which present distinct segmentation challenges due to the complex regional anatomy. Despite these inherent challenges, both methods demonstrated strong intra-rater reliability, with the sigmoid notch-based method showing slightly lower measurement variability than the lingula-based method. Furthermore, both workflows utilize open-source software, thereby ensuring broad accessibility for clinicians and researchers. Ultimately, the goal of this report is to facilitate the implementation of a semi-automatic segmentation approach that combines the computational efficiency of automated methods with the precision of manual refinement. When assessing a condyle volume, determining the inferior border of the volume of interest is important, as the other borders are determined by the segmentation process [ 20 ]. Different authors have used different landmarks as inferior borders of condylar segments [ 6 ]. Previous reports have suggested the lingula as a stable landmark for measuring condylar height in descriptive studies [ 16 ]. A possible rationale for presenting the mandibular lingula as a more stable landmark is its embryological origin. The development of the body of the mandible is guided by the Meckel cartilage, limited from the mental foramen to the mandibular lingula (posterior contour of the body). The condylar cartilage development is secondary to this event, occupying the space from the mandibular lingula to the glenoid cavity of the temporal bone. In that way, the uppermost point of the condylar unit is the condylar head, and its lowest point would be represented by the mandibular lingula [ 22 – 24 ]. Hence, it is proposed that the evaluation of the condylar unit should include the method ML, as it is the lowest part. The sigmoid notch is the depression between two mandibular skeletal units (the coronoid process and condyle). The sigmoid notch landmark is more susceptible to alterations in both skeletal units. Thus, it would not be stable when evaluating condyle length [ 22 ]. Another discussion regarding the assessment of condylar volumetric measurements is the choice between two-dimensional and 3D imaging modalities. The panoramic radiograph is a valuable screening tool in dentistry, but it provides limited value for assessing condylar hyperplasia due to limited image magnification, geometric distortion, and superimposed images [ 25 ]. The use of lateral radiographs associated with cephalometric measurements also presents limited value and it is very susceptible to multiple sources of error, including image magnification, superimposition of the images of structures, and errors in landmark identification, tracing, and measuring [ 26 ]. In contrast, CBCT offers superimposition-free images that are self-corrected for magnification, with a practical 1:1 measuring ratio, for accurate measurements of craniofacial structures [ 27 ]. There are several advantages of 3D over the 2D imaging techniques, including the more accurate, real size information in all dimensions of space. Furthermore, the 3D information on hard tissue is not highly dependent on head positioning, which might be a critical source of error in 2D imaging [ 28 ]. Volumetric information may improve a patient’s individual therapy, giving important anatomical information for understanding UCH pathology for what concerns growth’s direction and shape [ 29 , 30 ]. 3D rendering is based on a process called segmentation, which is described as the virtual separation of the anatomical region of interest with the removal of all other structures of non-interest for better visualization and analysis [ 31 , 32 ]. Segmentation can be performed manually, semi-automatically, or automatically [ 33 ]. Manual segmentation represents the gold standard for the 3D rendering of maxillofacial structures since it allows for the detection of areas with low bone density or with no well-defined boundaries due to their low contrast and proximity to other structures [ 14 ]. Operator subjectivity in determining the variable threshold is critical with manual segmentation and may significantly influence the reliability and accuracy of condylar segmentation from CBCT images [ 34 ]. Semiautomated technique utilizes thresholding and region growing to segment the condyle [ 35 , 36 ]. While many software options for DICOM analysis with semi-automatic segmentation exist, CBCT-based segmentation is not so commonly used in clinical practice due to usability issues, high computer requirements, and licensing costs. Free open-source DICOM viewers with segmentation algorithms are available, often developed by universities or research groups, but clinicians may be unaware of these options [ 9 ]. Engelbrecht et al concluded that measurements derived from landmarks on the condyle and lingual region of the mandible are less accurate than reality [ 14 ]. They evaluated twenty linear measurements from two segmentation protocols commercial segmentation (CS) and doctor’s segmentation (DS) groups. They found that the measurements of 3D models from the commercially segmented group were more accurate at the condylar region than those from the doctor segmentation group [ 14 ]. Accurate and reliable condylar segmentation from 3D images might be difficult to obtain efficiently when compared to other mandibular structures. A relatively low bone density of the condyles and intimate proximity with the articular disc have been suggested as reasons for the difficulty [ 14 ]. Previously, several studies have assessed different aspects such as reliability, different segmentation protocols, different software, and different landmarks [ 6 , 8 , 16 ]. Nolte et al performed volumetric measurements to quantify mandibular asymmetry in unilateral condylar hyperplasia. They found significant differences between the affected side and healthy side in segments of the condyle, ramus, and body in a group of patients, for both linear and volumetric measurements. The condylar region appeared to be the segment most affected by a significantly larger volume using Maxilim (Medicim NV, Mechelen, Belgium) to compute the volume. However, their study compared the patients with test subjects and did not include any post treatment evaluation [ 10 ]. Holte et al proposed a semi-automatic approach, which showed good to excellent reliability [ 8 ]. They performed 3D quantification and assessment of the TMJ from CBCT, including adaptive processes in the TMJ (adaptive Condylar changes, Glenoid Fossa Changes, Condylar positional changes), which are believed to contribute to the position of the mandible [ 8 , 37 ]. Garcia Sanz performed threshold-based volume segmentation on 6 cadaver heads and reported excellent intra-observer and inter-observer agreement [ 38 ]. But the operator had access and superimposed the scanned surface model of the condyle to aid in the volume segmentation process, thus likely resulting in substantially higher inter-observer reliability [ 38 ]. Da Silva et al eval
## Related Clinical Research

- [Habitual qat chewing and short-term response to conservative treatment for temporomandibular disor](https://medichelpline.com/clinical-feed/plos-one-8-habitual-qat-chewing-and-short-term-response-to-conservative-management-of.md)
- [Preventive Services Task Force Returns; Votes Held Privately After Yearlong Hiatus](https://medichelpline.com/clinical-feed/stat-news-2-at-first-preventive-services-panel-meeting-in-more-than-a-year-votes-are-cast.md)
- [Chronic evoked seizures worsen cognition and circadian behavior in APP/PS1 and PSEN2-N141I mice](https://medichelpline.com/clinical-feed/biorxiv-7-chronic-evoked-seizures-differentially-worsen-cognitive-function-and-long-term.md)
- [Anxiety-related distress and quality of life during chemotherapy: a dynamic network analysis](https://medichelpline.com/clinical-feed/pubmed-43068405.md) (DOI: 10.1007/s11136-026-04445-z)
- [Social determinants and quality of life in adults with functional limitations in low-income US com](https://medichelpline.com/clinical-feed/pubmed-43068430.md) (DOI: 10.1007/s11136-026-04447-x)

## Navigation
- [← Back to Dentistry Feed](https://medichelpline.com/clinical-feed/dentistry.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.