---
title: "Distributor vane geometry alters fertilizer spread uniformity in twin-disc broadcasters"
id: "plos-one-10-shaping-the-spread-influence-of-distributor-vane-design-on-fertilizer"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-10-shaping-the-spread-influence-of-distributor-vane-design-on-fertilizer"
content_type: "clinical_feed_article"
specialty: "General"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363472"
published_at: "2026-11-24T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Distributor vane geometry alters fertilizer spread uniformity in twin-disc broadcasters
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-10-shaping-the-spread-influence-of-distributor-vane-design-on-fertilizer
- **Specialty:** [General](https://medichelpline.com/clinical-feed/general.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363472)
- **Published At:** 2026-11-24T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- The study compared four custom vane geometries—**hollow-channel**, **double-channel**, **quad-channel**, and inclined-channel—on a twin-disc broadcaster using a standardized compound fertilizer (NPK 15-15-15). - Tests followed ASAE S341.4 bench and field procedures; all trials were performed in triplicate for bench work and four replications in the field, with PTO speed maintained at 540 min⁻¹ as verified by a tachometer. - Performance was evaluated by transverse distribution uniformity expressed as **coefficient of variation (CV, %)** across working widths; raw data and supporting files are reported in the source. - The quad-channel vane achieved the lowest CV measured (10.12%) at an effective working width of 14.64 m; this configuration produced the best precision but had a limited effective working width. - The hollow-channel vane produced an acceptable CV (14.87%) at 14.64 m while enabling a wider effective working width (reported as 14.64 m in the source); it was described as offering greater field efficiency through reduced overlap. - Double-channel and inclined-channel vane configurations produced insufficient transverse uniformity across tested working widths. - Statistical analysis: Levene’s test indicated homogeneity of variances; One-Way ANOVA found significant differences among vane types (F(3,12)=53.143, p < .001); Duncan’s multiple range test showed quad-channel CV significantly lower than other vane types. - Authors attributed quad-channel performance to improved balancing of radial and tangential particle velocity components at disc release, reducing erratic collisions and stabilizing lateral spread patterns; the source linked this to internal ribbing and guidance surface effects. - The source reported that optimizing vane internal geometry is a low-cost mechanical strategy to improve field-scale fertilizer efficiency and recommended quad-channel for precision applications and hollow-channel where wider working widths and throughput matter. - The source did not report certain specifics such as detailed rib dimensions beyond overall vane lengths, nor did it present long-term field crop or environmental outcome data; those outcomes were outside the reported experiments.
## Clinical Analysis & Structured Key Points
Shaping the spread: Influence of distributor vane design on fertilizer distribution uniformity | PLOS One Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click here . Article Authors Metrics Comments Media Coverage Reader Comments Figures Figures Abstract Achieving uniform fertilizer distribution with disc-type spreaders is critical for both crop nutrition and environmental sustainability, yet it remains challenging due to the numerous influencing parameters. This study specifically investigates the impact of distributor vane geometry on the coefficient of variation (CV, %) of twin-disc broadcasters. Four custom-designed vane configurations named hollow-channel, double-channel, quad-channel, and inclined-channel were developed and manufactured. Controlled bench tests were conducted using compound fertilizer in strict accordance with the ASAE S341.4 standard, with all trials performed in triplicate to ensure statistical reliability. The results revealed a clear trade-off between distribution precision and effective working width. The quad-channel vane delivered the highest distribution uniformity, achieving a CV of 10.12%, although its effective working width was limited to 14.64 meters. In contrast, the hollow-channel vane provided acceptable uniformity (CV of 14.87%) while enabling a substantially wider effective working width of 14.64 m, offering greater field efficiency through reduced pass-to-pass overlap. Statistical analysis confirmed that the vane geometry had a significant effect on the CV (p < 0.05). The superior performance of the quad-channel design is attributed to its ability to better balance the radial and tangential velocity components of granular particles at the point of disc release, thereby minimizing erratic collisions and stabilizing the lateral spread pattern. These findings provide actionable guidance for both manufacturers and end-users: the quad-channel vane is recommended for precision agriculture where application accuracy is paramount, whereas the hollow-channel vane serves as a practical, high-capacity alternative for large-scale operations where maximizing working width and minimizing fuel consumption take priority. This study underscores that optimizing vane geometry is a highly effective, low-cost strategy for improving field-scale fertilizer efficiency. Citation: Kömekçi F, Urkan E, Kömekçi C, Güler H, Aykas E (2026) Shaping the spread: Influence of distributor vane design on fertilizer distribution uniformity. PLoS One 21(11): e0363472. https://doi.org/10.1371/journal.pone.0363472 Editor: Paulo H. Pagliari, University of Minnesota, UNITED STATES OF AMERICA Received: February 26, 2026; Accepted: November 9, 2026; Published: November 24, 2026 Copyright: © 2026 Kömekçi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: All relevant data are within the manuscript and its Supporting Information files. Funding: This study was conducted under project number 16-ZRF-026 within the Ege University Scientific Research Projects program. The funders had no role in the study design, data collection and analysis, the decision to publish, or the preparation of the manuscript. Competing interests: The authors have declared that no competing interests exist. Introduction Precision fertilizer application is critical for optimizing crop yield, reducing input costs, and minimizing environmental contamination. Among the various spreading technologies, single-disc fertilizer spreaders were widely adopted in the 1950s, but since the 1970s, twin-disc spreaders have become the standard due to their better distribution uniformity and larger working widths. Uniformity in both systems depends not only on fertilizer properties (e.g., granule size, density, friction) but also on machine design and operational settings. Key structural parameters include disc and vane geometry, vane configuration (number and arrangement), feed opening characteristics, and feed radius, while operational factors such as peripheral speed and disc height above ground are equally influential [ 1 ]. Distributor vanes are among the most critical components, as they directly govern particle trajectories and effective spreading width [ 2 – 4 ]. Consequently, extensive research has examined the effects of vane angle [ 1 , 5 – 8 ], height [ 9 – 12 ], and number [ 8 , 13 , 14 ] on distribution evenness. For instance, Parish (2003) [ 15 ] tested five commercial walk-behind spreaders with varying vane profiles—from simple straight vanes on flat discs to mixed curved/straight configurations on concave discs. Yıldırım (2008b) [ 16 ] and Yıldırım & Kara (2012) [ 17 ] investigated the performance of single-disc spreaders with flat, combined, and backward-pitched circular vanes at different flow rates. More recently, Fulton et al. (2020) [ 4 ] examined the shapes of double-disc spreader vanes using potassium chloride fertilizer at multiple peripheral speeds and application rates. Notably, most commercial and experimental broadcaster vanes documented in the literature feature hollow, smooth cross-sections (e.g., ‘L,’ ‘Z,’ or ‘C’ shapes) designed solely around external curvature and release angles. While external vane geometry and rotational aerodynamics significantly affect fluid-particle guidance mechanisms, microscale boundary-layer interactions along the vane's internal guidance surface have been largely overlooked. In smooth-walled channels, bulk granular material suffers from chaotic intra-bed particle collisions, lateral rolling, and unconstrained bouncing, which broaden the dispersion angle at the disc periphery and compromise lateral uniformity. Surface structuring and ribbed guide vanes have shown substantial advantages in flow-direction control and kinetic boundary stabilization in related turbomachinery and fluid-solid handling systems, yet this concept has never been applied to agricultural centrifugal broadcasters. To bridge this critical engineering gap, this study introduces novel inner-fluted distributor vanes with raised longitudinal ribs along the guidance face. By comparing hollow-channel, double-channel, quad-channel, and inclined-channel profiles under standardized field conditions, this work provides a rigorous empirical and kinematic assessment of whether passive internal ribbing can stabilize particle-release trajectories and improve distribution uniformity. Materials and methods The overall experimental and analytical procedure of this study, which investigates the effect of different vane profiles on distribution uniformity, is summarized in the workflow presented in Fig 1 . Download: PNG larger image TIFF original image Fig 1. The workflow of the research. https://doi.org/10.1371/journal.pone.0363472.g001 The general features of the twin-disc fertilizer broadcaster ( Fig 2 ), which typically consists of a partially divided hopper, two fertilizer-spreading discs, two vanes with adjustable position angles located on the discs, and a gearbox that transmits motion to the discs, are listed in Table 1 . Download: PNG larger image TIFF original image Table 1. General features of the twin-disc fertilizer broadcaster. https://doi.org/10.1371/journal.pone.0363472.t001 Download: PNG larger image TIFF original image Fig 2. Twin-disc fertilizer broadcaster used in the study. https://doi.org/10.1371/journal.pone.0363472.g002 The galvanized sheet metal distributor discs located under the fertilizer hopper are equipped with two vanes ( Fig 3 ). The general characteristics of the fertilizer distributor discs are given in Table 2 . The transmission ratio between the tractor power take-off (PTO) speed and the fertilizer distributor disc speed is 0.70. Download: PNG larger image TIFF original image Table 2. General features of fertilizer distributor discs. https://doi.org/10.1371/journal.pone.0363472.t002 Download: PNG larger image TIFF original image Fig 3. Fertilizer distributor discs. https://doi.org/10.1371/journal.pone.0363472.g003 To systematically isolate the mechanical effect of vane internal geometry from confounding material interactions, a single, standardized compound fertilizer (NPK 15-15-15) was deliberately utilized across all experimental treatments. Granular fertilizer physical attributes such as particle density, shape factor, coefficient of restitution, and particle-to-metal friction substantially dictate spreading dynamics. Testing multiple fertilizers simultaneously would introduce multi-factor confounding interactions, hindering the precise identification of whether swath variances originated from vane rib geometry or shifting material physical properties. By fixing the granular medium as a rigorously characterized benchmark, all observed trajectory alterations could be directly attributed to the geometric profiles of the vanes. Bulk density, angle of repose, moisture content, and granule size of the compound fertilizer used in the experiments were determined according to Alayunt et al., 2009; Komekci et al., 2024; TS 2832, 2018; and TS 1235, 1996 [ 8 , 18 – 20 ] and are given in Table 3 . Download: PNG larger image TIFF original image Table 3. Physical properties of compound fertilizer. https://doi.org/10.1371/journal.pone.0363472.t003 The angle of repose (°) was calculated using Equation 1. For this measurement, an apparatus comprising a funnel positioned 12.5 cm above the surface, with a closable lid at its outlet, was utilized. In Equation 1, 𝛼 represents the angle of repose (°), h is the height of the discharge spout from the surface (12.5 cm), is the average diameter of the fertilizer pile measured across four different regions (mm), and d i is the funnel outlet diameter (25 mm). (Equation 1) Abrasion resistance (%) was measured by placing a 100 cm³ fertilizer sample into a drum containing 50 steel balls (7.9 mm diameter) and rotating it at 30 min ⁻ ¹ for 10 minutes. The treated fertilizer was then sieved through a 1-mm aperture sieve for 5 minutes, with the results calculated using Equation 2. (Equation 2) The moisture content (%) was determined via the oven-drying method using a Nüve FN 120 oven. Initially, the prepared samples were weighed and then dried at 70°C for 24 hours. After removing the samples from the oven, they were reweighed, and the final moisture content was calculated using Equation 3. In Equation 3, R represents the moisture content (%), m 1 is the mass of the empty sample container (g), m 2 is the total mass of the initial fertilizer and container (g), and m 3 denotes the total mass of the dried fertilizer and container (g). (Equation 3) Fertilizer flowability was evaluated using a stainless steel funnel. For calibration, spherical glass beads (4 ± 0.3 mm in diameter and 2.5 kg dm ⁻ ³ density) were used. Initially, the time required for a 2 kg mass of glass beads to pass through the funnel was recorded. Subsequently, a 2 kg fertilizer sample was discharged through the same funnel, and its flow time was measured. The final flowability of the fertilizer was then calculated using Equation 4. In Equation 4, F represents the fertilizer flowability, is the mean flow time for a 2 kg mass of glass beads (s), and is the mean flow time for a 2 kg fertilizer sample (s). (Equation 4) To determine the fertilizer particle-size distribution, a sieve analysis was conducted using 4, 3.35, 2, and 1 mm screens, chosen based on the expected particle-size range. Samples of 100 g were prepared and agitated using a Retsch circular-motion sieve shaker for 10 minutes, with all tests performed in triplicate. Following agitation, the mass retained on each sieve was weighed, and the mass percentage of fertilizer on each screen ( X n ) was calculated using Equation 5. In Equation 5, m n is the mass retained on the n th sieve (g), m T is the total mass of the fertilizer sample (g), and X n represents the mass percentage of the fertilizer retained on the n th sieve (%). (Equation 5) In Equation 6, d 50 represents the mass median diameter (mm), m n is the mass of the fertilizer retained on the n th sieve (g), and d n indicates the mean aperture diameter of the n th sieve (mm) (Equation 6) Fertilizer flow calibration was performed on a stationary test bench powered by an 11 kW AC electric motor. PTO shaft rotation was precisely regulated at 540 ± 1 min ⁻ ¹ using an ABB-ACS550 variable-frequency drive (VFD), which provided closed-loop torque control and eliminated motor slip under varying hopper loads. Operational disc speed was continuously verified before each trial run using a calibrated dual-mode digital tachometer (Lutron DT-2236; accuracy: ±(0.05% + 1 digit), optical resolution: 0.1 min ⁻ ¹). The target flow rate of 0.839 kg s ⁻ ¹ was established to match a typical field application rate of 30 kg da ⁻ ¹. The vanes prepared for use in the experiments were designed and manufactured as “C“shaped with hollow channel, double-channel, quad-channel, and inclined-channel. Each disc has two vanes with lengths of 210 mm and 300 mm, respectively. The designs of the vanes produced are shown in Fig 4 . In addition, the geometric parameters of the vane combinations are provided in S1 File . Download: PNG larger image TIFF original image Fig 4. Vane combinations. a: hollow channel, b: double-channel, c: quad-channel, d: inclined-channel. https://doi.org/10.1371/journal.pone.0363472.g004 To determine the effect of hollow channel, double-channel, quad-channel, and inclined-channel distributor vanes on fertilizer distribution uniformity in the twin-disc fertilizer broadcaster, field experiments were conducted. The experiments were conducted at the Faculty of Agriculture, Ege University, with four replications (including two replications per single tractor pass). Parish (2002) [ 9 ], reported that uniform fertilizer distribution was impaired when PTO speed fell below 540 min -1 . Therefore, PTO speed was measured with a Lutron DT-2236 tachometer before each experiment. The standard PTO speed used in field experiments with the twin-disc fertilizer broadcaster is 540 min ⁻ ¹. Plastic collection trays measuring 500 mm × 400 mm × 100 mm conforming strictly to ASAE S341.4 specifications were deployed in two parallel transverse rows ( Fig 5 ). Each tray was equipped with internal anti-spill cellular louvers (dividers) to prevent granule ricochet, external bounce-out, and splatter upon impact. All field experiments were performed within the wind speed and hopper fill level limits prescribed by the ASAE S341.4 [ 21 ] and ASAE 281.3 [ 22 ] standards. The experiments followed the procedures outlined in Kömekçi et al. (2024) [ 8 ] and the raw experiment data is available in S2 File . The results were assessed using the evaluation criteria presented in Table 4 of [ 23 ]. In addition, to perform statistical analyses, instead of averaging the repetitions, four CV (%) values were obtained by overlapping swath from each repetition. These values were then subjected to normality and homogeneity of variances tests using Shapiro-Wilk and Levene’s tests, respectively. Since the assumption of homogeneity of variances was satisfied, the One-Way ANOVA was conducted to evaluate the effect of different vane types on fertilizer distribution uniformity, and post hoc comparisons using Duncan's Multiple Range Test were conducted to determine the specific differences in fertilizer distribution uniformity among the vane types. Download: PNG larger image TIFF original image Table 4. Fertilizer distribution uniformity (%, CV) criteria [ 8 , 23 ]. https://doi.org/10.1371/journal.pone.0363472.t004 Download: PNG larger image TIFF original image Fig 5. Arrangement of collection containers and field experiment. https://doi.org/10.1371/journal.pone.0363472.g005 Results The CV (%) values obtained in the experiments with vane combinations for different working widths are shown in Fig 6 . The model equations shown in the graphs represent the CV (y, %) values corresponding to the effective working width (x, m) for each vane combination. Download: PNG larger image TIFF original image Fig 6. The CV (%) values obtained in the study with the vane combinations for different working widths. a: hollow channel, b: double-channel, c: quad-channel, d: inclined-channel. https://doi.org/10.1371/journal.pone.0363472.g006 Levene’s test revealed that the assumption of homogeneity of variances was satisfied, F (3, 12) = 1.325, p = .312. Since the assumption of homogeneity of variances was satisfied, the One-Way ANOVA was conducted to evaluate the effect of different vane types on fertilizer distribution uniformity, and post hoc comparisons using Duncan's Multiple Range Test were conducted to determine the specific differences in fertilizer distribution uniformity among the vane types. The results indicated a statistically significant difference in distribution uniformity among the vane types, as indicated by F (3, 12) = 53.143, p < .001. Post-hoc comparisons using Duncan's Multiple Range Test revealed that the CV (%) on minimum three working width for the quad-channel vane combination (M = 12.75, SD = 2.13) was significantly higher than the hollow-channel vane combination (M = 16.81, SD = 1.75), double-channel vane combination (M = 21.75, SD = 0.68), and inclined-channel vane combination (M = 26.20, SD = 1.50). To determine acceptable distribution uniformity according to Table 4 , CV (%) values and evaluations of transverse distribution uniformity for different working widths, determined from open field experiments, are presented in Table 5 . In experiments with the hollow-channel vanes, the minimum coefficient of variation was 14.87%, corresponding to a working width of 14.64 m. Although this distribution uniformity is classified as acceptable, when the working width was increased to 16.51 m, a slight increase in CV was observed. However, the CV (%) remained below the acceptable limit. In the experiments with the compound fertilizer and the quad-channel vane configuration, the lowest coefficient of variation was 10.12%. Under this condition, the working width was 14.64 m, which is considered acceptable. However, since greater working widths are generally preferred in twin-disc fertilizer broadcasters, the width can be increased to 17.76 m. Therefore, both configurations can be considered to provide satisfactory performance, as indicated in Table 5 . The transverse fertilizer distribution uniformity values obtained using double-channel and inclined-channel vanes were insufficient at all effective working widths. Download: PNG larger image TIFF original image Table 5. Results of the field experiments. https://doi.org/10.1371/journal.pone.0363472.t005 The graphs of the best transverse fertilizer distribution uniformity experiments are shown in Fig 7 . The lowest CV (%) values were achieved at a working width of 14.64 m with all vane combinations. Download: PNG larger image TIFF original image Fig 7. The best CV (%) values obtained in the study with the vane combinations. a: hollow channel, b: double-channel, c: quad-channel, d: inclined-channel. https://doi.org/10.1371/journal.pone.0363472.g007 In light of these results, distributor vane designs significantly influence fertilizer distribution uniformity, offering the potential to enhance pattern uniformity and extend the effective working width. Discussion Several studies have examined how the angle [ 1 , 5 – 8 ], height [ 9 – 12 ], and number of distributor vanes [ 8 , 13 , 14 ] influence fertilizer distribution uniformity. Investigating the impact of vane geometry, Parish (2003) [ 15 ] conducted experiments using granular fertilizer on five wheel-driven walk-behind broadcasters. The tested configurations included broadcasters with four straight v
## Related Clinical Research

- [Decline in HIV testing among Zambian adolescent girls after 2018: DHS decomposition analysis](https://medichelpline.com/clinical-feed/plos-one-3-reversal-in-hiv-testing-uptake-among-adolescent-girls-in-zambia-2007-2024-a.md)
- [Servant leadership weakens the link between attachment avoidance and contextual job performance](https://medichelpline.com/clinical-feed/plos-one-11-the-buffering-role-of-perceived-servant-leadership-in-the-association-between.md)
- [Paperwork, Not Employment, Drove Early Medicaid Losses in Nebraska](https://medichelpline.com/clinical-feed/kff-health-news-3-it-s-the-paperwork-not-the-work-causing-enrollees-to-lose-medicaid-in-nebraska.md)
- [Sticker Shock vs. Hidden Costs: Debating the Price of Single-Payer and Medicare for All](https://medichelpline.com/clinical-feed/kff-health-news-1-sticker-shock-looms-as-a-major-challenge-in-push-for-single-payer-healthcare.md)
- [U.S. Visa Policies Linked to Drop in International Graduate Students and Biomedical Ph.D. Entrants](https://medichelpline.com/clinical-feed/stat-news-1-despite-stalling-in-court-trump-restrictions-on-foreign-students-have-had-a.md)

## Navigation
- [← Back to General Feed](https://medichelpline.com/clinical-feed/general.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.