---
title: "High blood lead levels in pregnant women in Amran, Yemen linked to prior spontaneous abortion"
id: "plos-one-19-elevated-blood-lead-levels-among-pregnant-women-in-amran-yemen-socio"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-19-elevated-blood-lead-levels-among-pregnant-women-in-amran-yemen-socio"
content_type: "clinical_feed_article"
specialty: "General"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363160"
published_at: "2026-11-20T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# High blood lead levels in pregnant women in Amran, Yemen linked to prior spontaneous abortion
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-19-elevated-blood-lead-levels-among-pregnant-women-in-amran-yemen-socio
- **Specialty:** [General](https://medichelpline.com/clinical-feed/general.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363160)
- **Published At:** 2026-11-20T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- Cross-sectional study of 150 pregnant women in Amran, Yemen, conducted August–November 2024 across four antenatal clinics. Data collection combined structured interviews and venous blood sampling analyzed by atomic absorption spectrophotometry. - The cohort showed a median **blood lead level** (BLL) of 40.8 µg/dL (IQR 19.0–62.0); values ranged from 1.0 to 143.0 µg/dL. The mean BLL reported was 43.5 µg/dL (±28.3). - A critically high prevalence was observed: 124 of 150 participants (82.7%) had BLLs > 10 µg/dL, using 10 µg/dL as the study threshold for elevated exposure. - In univariate screening, a history of spontaneous abortion was associated with elevated BLLs (p = 0.001); residential proximity to petrol stations/battery recycling sites and current smoking showed positive but non-significant trends. - Multivariable logistic regression (adjusting for variables screened into the model) identified prior spontaneous abortion as the only statistically significant independent predictor (AOR = 5.88; 95% CI: 1.66–20.89; p = 0.006); the wide CI reflects imprecision noted by the authors. - Environmental and behavioral exposures assessed included proximity to petrol/battery sites (30%), para-occupational exposure (12.7%), khat chewing (60%), cosmetic use (68.7%), and metal cookware use (48%). - Laboratory methods: venous samples in K2 EDTA tubes; analysis by UNICAM 929 AA atomic absorption. Quality controls included calibration with TraceCERT standards, duplicate testing (10% samples), and NIST reference materials; analytical precision and recovery rates were reported. - The authors call for immediate source investigations, strengthened environmental regulation, and routine antenatal BLL screening in Amran; these are specific recommendations given the high prevalence. - The study excluded women with chronic illnesses and direct occupational heavy-metal exposure; sample size and some covariate distributions yielded wide CIs and limited precision in adjusted estimates.
## Clinical Analysis & Structured Key Points
Elevated blood lead levels among pregnant women in Amran, Yemen: Socio-demographic correlates and associations with a history of spontaneous abortion | PLOS One Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click here . Article Authors Metrics Comments Media Coverage Reader Comments Figures Figures Abstract Background Lead exposure in pregnant women is a critical public health concern, particularly in resource-limited settings where environmental regulations are less stringent. Prenatal lead exposure (Pb) is associated with various adverse maternal and fetal outcomes. Therefore, this study aimed to assess blood lead levels (BLLs) among pregnant women in Amran, Yemen, and to identify health risks associated with environmental, behavioral, and socio-demographic factors. Methods A cross-sectional multi-center study was conducted between August and November 2024, involving a sample of 150 pregnant women (aged 20–41 years) recruited across public and private healthcare facilities in Amran. Data were collected via structured questionnaires, and venous blood samples collected in K 2 EDTA were analyzed using atomic absorption spectrophotometry (UNICAM 929AA). Statistical analysis was performed using SPSS version 24, with a significance threshold of P 10 μg/dL (P) to 0.054 as determined by Al-Jawadi et al. [ 13 ], since there were no local published studies. By substituting the values, the final sample size was targeted at 79. Taking a design Effect (DEff) of 1.5 to account for potential intra-facility correlation across our multi-center design, as pregnant women utilizing specific urban clinics may share localized geographic point-sources or micro-regional water pipelines, accounting for the multi-center design involving different public and private healthcare facilities (79X1.5=119) and an expected non response rate of 10% added to the total (119 + 11.9), the final sample size was targeted at 131. To further increase statistical power, a final sample of 150 participants was recruited. Participants were recruited across four antenatal clinics (two public facilities and two private centers), yielding specific clinic sample blocks of N = 42, N = 38, N = 35, and N = 35 respectively. Public facilities required small nominal administrative registration fees, while private clinics operated under a full out-of-pocket fee-for-service paradigm. A total of 14 women declined participation upon initial recruitment offer due to time limitations or familial resistance to phlebotomy, yielding a non-response rate of 8.5% (14/164). Ethical statement Ethical approval for this study was granted by the Institutional Review Board (IRB) of the Faculty of Medicine at Amran University (Approval Number: 130–09-IMC). The study was conducted in accordance with the ethical principles outlined in the Declaration of Helsinki. All participants were informed about the purpose of the study, assured of confidentiality, and provided written informed consent prior to participation. Participation was voluntary, and respondents could withdraw at any time without consequence. All methods and study procedures were carried out in accordance with relevant guidelines and regulations. Data and sample collection Data about the potential risk factors, socio-demographic characteristics, lifestyle habits, environmental exposures, use of cosmetics and personal care products, and pregnancy history were collected using a structured questionnaire ( S2 File ). The questionnaire was developed in English, systematically translated into Arabic by independent bilingual experts, and back-translated to ensure semantic equivalence. The final validated Arabic version was administered via face-to-face interviews by trained research nurses; the English version provided in S2 File serves strictly for international reporting and replication purposes. Residential proximity to petrol stations and battery recycling sites was evaluated as a single composite variable because these operations are frequently co-located within the study region due to shared local infrastructure and a lack of municipal zoning enforcement. Maternal occupational history was not collected as an independent demographic category due to the specific socio-cultural context of the traditional tribal community in Amran, where local customs and cultural norms restrict women from engaging in external or industrial employment. Instead, occupational risk was captured via the ‘Para-occupational exposure’ variable (Family member working in lead-related sites). This binary variable (Yes/No) was defined as indirect, take-home exposure resulting from a spouse or cohabitating family member actively employed in a lead-associated trade (e.g., automotive repair, welding, plumbing, or battery maintenance) that could introduce secondary lead dust into the domestic environment. Venous blood samples (5 mL) were collected from each participant by trained nurses using certified lead-free BD Vacutainer® trace element tubes containing K 2 EDTA (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) . The samples were immediately stored at 4°C and transported to the laboratory for lead analysis within 24 hours. Blood lead levels determination Blood lead concentrations were measured using atomic absorption spectrophotometry (UNICAM 929 AA, Thermo Scientific, UK) [ 2 ]. The spectrophotometer was calibrated daily using certified lead standard solutions (TraceCERT®, Sigma-Aldrich) across a concentration range of 5–50 µg/dL with validated calibration curves with validated calibration curves (R 2 > 0.995) required prior to sample execution. Quality control procedures included the use of reagent blanks, duplicate analysis for 10% of samples (intra-assay CV 10 µg/dL). As illustrated in Fig 1 , a critically high prevalence of lead exposure was observed: 124 participants (82.7%) exhibited elevated BLLs (>10 µg/dL), while only 26 participants (17.3%) had levels within the lower threshold (≤10 µg/dL). Download: PNG larger image TIFF original image Fig 1. Prevalence of elevated blood lead levels (>10 µg/dL) among the sampled pregnant women in Amran, Yemen. The bar chart illustrates the percentage and absolute frequency of participants falling above and below the designated 10 µg/dL threshold. https://doi.org/10.1371/journal.pone.0363160.g001 Factors associated with elevated blood lead levels The associations between socio-demographic characteristics, risk factors, and elevated BLLs are illustrated in Table 2 . Univariate analysis revealed no statistically significant associations for the majority of socio-demographic characteristics, with the notable exception of a history of spontaneous abortion ( p = 0.001). Residential proximity to petrol stations and battery recycling sites demonstrated an increased frequency trend within the elevated cohort (33.1% vs. 15.4%), though this association did not reach formal statistical significance ( p = 0.074). Similarly, higher frequencies of elevated BLLs (>10 μg/dL) were observed among younger participants, urban residents, and those reporting khat chewing, use of metal cookware, or application of cosmetics and skin-lightening creams did not yield statistically significant differences between the two groups. Notably, the relative distribution of reported clinical symptoms—including hypertension, tingling in extremities, hand tremors, difficulty concentrating, and weakness or nervousness—was statistically comparable across both the reference (≤ 10 μg/dL) and elevated (> 10 μg/dL) BLL groups ( p > 0.05). Download: PNG larger image TIFF original image Table 2. Comparison of socio-demographic characteristics and risk factors associated with blood lead levels (N = 150). https://doi.org/10.1371/journal.pone.0363160.t002 Multivariable analysis of factors associated with elevated BLLs A binary multivariable logistic regression analysis was performed to identify independent factors associated with elevated BLLs, adjusting for potential covariates ( Table 3 ). In the univariate (crude) analysis, a history of spontaneous abortion was significantly associated with elevated BLLs (COR = 6.31, 95% CI: 1.80–22.13, p = 0.001). Although participants residential proximity to petrol stations and battery recycling sites (COR = 2.72, 95% CI: 0.88–8.40, p = 0.074) and those who reported current smoking (COR = 4.00, 95% CI: 0.89–17.90, p = 0.053) showed higher odds of elevated BLLs, these associations did not reach statistical significance at the 5% level. Download: PNG larger image TIFF original image Table 3. Crude and adjusted odds ratios for factors associated with elevated BLLs (>10 µg/dL) among the sample. https://doi.org/10.1371/journal.pone.0363160.t003 After adjusting for all covariates included in the multivariable model, history of spontaneous abortion remained the only statistically significant predictor. Participants with a history of spontaneous abortion had 5.88 times higher odds of having elevated blood lead levels compared to those without such a history (AOR = 5.88, 95% CI: 1.66–20.89, p = 0.006). Associations for proximity to petrol stations or battery recycling sites (AOR = 2.46, 95% CI
## Related Clinical Research

- [Long-term complication profiles after transsphenoidal vs transcranial resection of adult craniopha](https://medichelpline.com/clinical-feed/plos-one-9-long-term-complication-profiles-following-transsphenoidal-and-transcranial.md)
- [Cardiometabolic multimorbidity among Ghanaian clinic patients: clinical, lifestyle and genetic cor](https://medichelpline.com/clinical-feed/plos-one-19-cardiometabolic-multimorbidity-and-associated-clinical-lifestyle-and-genetic.md)
- [Pregnancy Outcomes After Prenatal Prescription Stimulant Use in Individuals with Opioid Use Disord](https://medichelpline.com/clinical-feed/medrxiv-4-maternal-and-neonatal-outcomes-associated-with-prenatal-prescription-stimulant.md)
- [Traffic‑Light Lifestyle Program in an Integrative Clinic: Real‑World Patient‑Reported Outcomes](https://medichelpline.com/clinical-feed/medrxiv-15-real-world-outcomes-of-a-traffic-light-approach-to-lifestyle-modification-in.md)
- [Postpartum Glycemic Control and Links to MMP-9, ET-1, Hypertension, and Dyslipidemia in Women with](https://medichelpline.com/clinical-feed/pubmed-43061853.md) (DOI: 10.1080/10641955.2026.2753956)

## Navigation
- [← Back to General Feed](https://medichelpline.com/clinical-feed/general.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.