title: "Single‑camera vs eight‑camera pose estimation for spatiotemporal gait measures"
id: "plos-one-7-comparative-evaluation-of-single-and-multiple-camera-based-pose-estimation"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-7-comparative-evaluation-of-single-and-multiple-camera-based-pose-estimation"
content_type: "clinical_feed_article"
specialty: "Neurology"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369"
published_at: "2026-11-20T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Single‑camera vs eight‑camera pose estimation for spatiotemporal gait measures
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-7-comparative-evaluation-of-single-and-multiple-camera-based-pose-estimation
- **Specialty:** [Neurology](https://medichelpline.com/clinical-feed/neurology.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369)
- **Published At:** 2026-11-20T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- Investigators compared a single iPad camera pose‑estimation workflow with an eight‑camera markerless motion‑capture (MMC) reference to assess spatiotemporal gait parameters. - The cohort comprised 36 healthy young adults (mean age 18.7 years); validity analyses used 458 paired trials from Visit 1, reliability used 33 participants with complete four‑visit data. - The single‑camera recordings were captured on an 11‑inch iPad Pro at 30 Hz; the eight‑camera reference (KinaTrax) sampled at 100 Hz and produced three‑dimensional trajectories processed in Visual 3D. - MediaPipe Pose (model_complexity = 2) and OpenCV were used to extract two‑dimensional landmarks from the single‑camera videos; spatial reconstruction and gait‑event detection were then applied (source did not report full algorithmic details). - Within‑participant repeated‑measures correlations showed the strongest agreement for **gait speed** (r_rm = 0.588), then stance duration (r_rm = 0.528), cycle time (r_rm = 0.515), and cadence (r_rm = 0.446); step and stride lengths had weaker correlations (~0.327–0.328), and swing duration was not significantly associated (p = 0.599). - Mean system differences were small but proportional bias affected all seven gait variables; bias varied by measurement magnitude and by walking condition. - Walking condition (usual, bag‑carrying with a 4.5‑kg load, phone‑use with self‑selected activity) influenced bias for cadence, gait speed, cycle time, step length, and stride length. - Test‑retest absolute‑agreement ICCs for single‑camera measures ranged from 0.499 to 0.862 across parameters and conditions; **gait speed** showed good reliability across conditions, swing duration the poorest reliability. - The authors concluded single‑camera MMC may be feasible for selected planar spatiotemporal outcomes, notably **gait speed**, when accessibility is prioritized, but single‑camera and multi‑camera approaches should not be considered interchangeable. - Limitations reported in the source included lower temporal resolution (30 Hz vs 100 Hz), unquantified participant depth relative to the camera, manual pairing requirements, and absence of higher‑frame‑rate single‑camera evaluation in this secondary analysis.
## Clinical Analysis & Structured Key Points
[ Skip to main content ](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#main-content) Advertisement * [plos.org](https://plos.org/) * [Create account](https://community.plos.org/registration/new) * [Sign in](https://journals.plos.org/user/secure/login?page=%2Fplosone%2Farticle%3Fid%3D10.1371%2Fjournal.pone.0363369) * * About * Browse * Publish * [](https://journals.plos.org/plosone/ "PLOS One") * Search [advanced search](https://journals.plos.org/plosone/search) * [Browse Topics](https://journals.plos.org/plosone/subjectAreaBrowse) Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click [here](https://github.com/PLOS/plos-thesaurus/blob/master/README.md "Link opens in new window"). [](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369) [](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369) * 0 [Save](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#savedHeader) [Total Mendeley and Citeulike bookmarks.](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#savedHeader) * 0 [Citation](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#citedHeader) [Paper's citation count computed by Dimensions.](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#citedHeader) * 48 [View](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#viewedHeader) [PLOS views and downloads.](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#viewedHeader) * 0 [Share](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#discussedHeader) [Sum of Facebook, Twitter, Reddit and Wikipedia activity.](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369#discussedHeader) Open Access Peer-reviewed Research Article # Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation * Bethany Weber, Roles Data curation, Formal analysis, Methodology, Validation, Writing – original draft Affiliation Department of Kinesiology and Sport Sciences, University of Miami, Coral Gables, Florida, United States of America [ ![ORCID logo](https://journals.plos.org/resource/img/orcid_16x16.png) https://orcid.org/0009-0006-3068-4660 ](https://orcid.org/0009-0006-3068-4660 "ORCID Registry") ⨯ * Brandon Schoenwether, Roles Conceptualization, Data curation, Investigation, Methodology, Project administration, Writing – original draft Affiliation Department of Kinesiology and Sport Sciences, University of Miami, Coral Gables, Florida, United States of America ⨯ * Tyler Booth, Roles Data curation, Formal analysis, Writing – original draft Affiliation Department of Kinesiology and Sport Sciences, University of Miami, Coral Gables, Florida, United States of America ⨯ * Megan McFarland, Roles Investigation, Methodology, Project administration, Writing – review & editing Affiliation Department of Psychology, University of Miami, Coral Gables, Florida, United States of America ⨯ * Jennifer Britton, Roles Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Supervision, Writing – review & editing Affiliation Department of Psychology, University of Miami, Coral Gables, Florida, United States of America ⨯ * Moataz Eltoukhy Roles Conceptualization, Investigation, Methodology, Project administration, Resources, Supervision, Writing – review & editing * E-mail: meltoukhy@miami.edu Affiliations Department of Kinesiology and Sport Sciences, University of Miami, Coral Gables, Florida, United States of America, Department of Industrial and Systems Engineering, University of Miami, Coral Gables, Florida, United States of America, Department of Physical Therapy, University of Miami Miller School of Medicine, Miami, Florida, United States of America [ ![ORCID logo](https://journals.plos.org/resource/img/orcid_16x16.png) https://orcid.org/0000-0003-3120-6944 ](https://orcid.org/0000-0003-3120-6944 "ORCID Registry") ⨯ # Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation * Bethany Weber, * Brandon Schoenwether, * Tyler Booth, * Megan McFarland, * Jennifer Britton, * Moataz Eltoukhy ![PLOS](https://journals.plos.org/resource/img/logo-plos-full-color.svg) x * Published: November 20, 2026 * * [Article](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369) * [Authors](https://journals.plos.org/plosone/article/authors?id=10.1371/journal.pone.0363369) * [Metrics](https://journals.plos.org/plosone/article/metrics?id=10.1371/journal.pone.0363369) * [Comments](https://journals.plos.org/plosone/article/comments?id=10.1371/journal.pone.0363369) * [Media Coverage](http://plos.altmetric.com/details/doi/10.1371/journal.pone.0363369) * [Abstract](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#abstract0) * [Introduction](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec001) * [Materials and methods](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec002) * [Results](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec011) * [Discussion](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec014) * [Conclusion](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec015) * [Supporting information](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec016) * [Acknowledgments](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#ack) * [References](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#references) * [Reader Comments](https://journals.plos.org/plosone/article/comments?id=10.1371/journal.pone.0363369) * [Figures](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369) ## Abstract Single-camera pose estimation may provide a more accessible approach to measure a person’s walking patterns (i.e., gait analysis) than multi-camera markerless motion capture (MMC), but its validity and test-retest reliability remain unclear. This study evaluated spatiotemporal gait parameters from a single iPad camera against an eight-camera MMC reference system across four visits, two weeks apart. Thirty-six healthy adults (18.7 ± 1.7, ranging 18‒27 years) completed usual-gait, bag-carrying, and phone-use walking conditions. Validity analyses included 458 paired trials from Visit 1 and used repeated-measures and mixed-effects methods. Reliability analyses included 33 participants with complete four-visit data and evaluated absolute agreement of single visit-level measurements. Using repeated-measures correlation, the strongest within-participant association between systems was gait speed (rrm = 0.588), followed by stance duration (rrm = 0.528), cycle time (rrm = 0.515), and cadence (rrm = 0.446; all _p_ < 0.001). Step length, calculated as half of stride length, and stride length showed weaker associations (rrm = 0.327 and 0.328; both _p_ < 0.001), whereas swing duration was not significantly associated (_p_ = 0.599). Independent step length and left−right step-length asymmetry were not evaluated. Mean system differences were small, but significant proportional bias was present for all seven gait variables, indicating that system differences changed with measurement magnitude. Walking condition influenced bias for cadence, gait speed, cycle time, step length, and stride length. Test-retest reliability varied by parameter and condition, with absolute-agreement intraclass correlation coefficients ranging from 0.499 to 0.862. Gait speed demonstrated good reliability across all three conditions, step and stride length demonstrated their highest reliability during the phone condition, and swing duration consistently demonstrated the lowest reliability. These findings support the feasibility of single-camera MMC for selected spatiotemporal gait outcomes, particularly gait speed, when accessibility and reduced equipment requirements are priorities. However, the approaches should not be considered interchangeable. Multi-camera MMC may remain better suited when three-dimensional reconstruction or more comprehensive spatial and temporal characterization is required. ## Figures ![Fig 2](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.g002) ![Table 3](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t003) ![Table 4](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t004) ![Table 1](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t001) ![Fig 1](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.g001) ![Table 2](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t002) ![Fig 2](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.g002) ![Table 3](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t003) ![Table 4](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t004) ![Table 1](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t001) ![Fig 1](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.g001) ![Table 2](https://journals.plos.org/plosone/article/figure/image?size=inline&id=10.1371/journal.pone.0363369.t002) **Citation:** Weber B, Schoenwether B, Booth T, McFarland M, Britton J, Eltoukhy M (2026) Comparative evaluation of single and multiple camera-based pose estimation methods for gait spatiotemporal parameter estimation. PLoS One 21(11): e0363369. https://doi.org/10.1371/journal.pone.0363369 **Editor:** Jyotindra Narayan, Indian Institute of Technology Patna, INDIA **Received:** September 9, 2026; **Accepted:** November 7, 2026; **Published:** November 20, 2026 **Copyright:** © 2026 Weber et al. This is an open access article distributed under the terms of the [Creative Commons Attribution License](http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. **Data Availability:** All relevant data are within the manuscript and its [Supporting Information](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#sec016) files. **Funding:** The author(s) received no specific funding for this work. **Competing interests:** NO authors have competing interests. ## Introduction Gait analysis is widely used to quantify the spatial and temporal characteristics of walking and evaluate functional movement across clinical and research settings [[1](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref001)–[5](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref005)]. Gait analysis provides objective information that supplements observation and may contribute to diagnosis, treatment planning, and monitoring of functional change over time [[1](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref001)–[5](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref005)]. Commonly reported gait outcomes include spatiotemporal parameters, such as‒ gait speed, cadence, step length, stride length, gait cycle time, and stance and swing durations [[3](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref003),[4](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref004)]. These measures characterize the timing and distance components of walking and have demonstrated sensitivity to functional impairments associated with conditions such as knee osteoarthritis and multiple sclerosis [[6](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref006),[7](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref007)]. Gait characteristics may also vary with psychological and cognitive state, further illustrating the sensitivity of spatiotemporal measures to changes in human function [[8](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref008),[9](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref009)]. The objective assessment of gait relies on a variety of motion-analysis technologies, each with distinct strengths and limitations that have driven the development of newer approaches. These technologies include instrumented walkways, wearable inertial sensors, and optical motion-capture systems [[3](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref003),[4](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref004),[10](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref010)]. Multi-camera optical marker-based motion capture is widely regarded as a reference method for biomechanical movement analysis because it permits three-dimensional reconstruction of body-segment motion [[3](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref003)–[5](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref005)]. However, marker-based systems require specialized laboratory infrastructure, participant preparation, and accurate placement of reflective markers on anatomical landmarks. Measurement may also be affected by marker-placement variability and movement of markers relative to the underlying skeletal structures [[1](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref001),[3](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref003)–[5](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref005)]. These limitations have contributed to increasing interest in markerless motion capture (MMC) approaches that estimate human movement directly from video. Advances in computer vision and artificial intelligence have enabled MMC systems to identify anatomical landmarks from video and reconstruct human movement without physical markers [[10](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref010),[11](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref011)]. Multi-camera MMC systems use synchronized views to reconstruct three-dimensional body trajectories and have demonstrated promising validity for spatiotemporal gait analysis in healthy adults and clinical populations [[10](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref010),[12](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref012)–[15](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref015)]. Previous studies using artificial intelligence driven multi-camera MMC have reported favorable agreement with established reference systems for variables including gait speed, stride length, step length, and several temporal parameters [[12](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref012),[14](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref014),[15](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref015)]. Systematic reviews similarly indicate that spatiotemporal gait measures are among the more accurately estimated variables obtained using contemporary markerless approaches [[10](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref010),[11](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref011)]. Reliability is also necessary if markerless systems are to be used for repeated gait assessment. Previous studies have demonstrated acceptable to excellent test-retest reliability for multiple spatiotemporal parameters obtained using multi-camera MMC [[16](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref016),[17](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref017)]. For example, Schoenwether et al. [[17](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref017)] demonstrated high between-session reliability for gait measures derived from an eight-camera artificial intelligence-driven MMC system in healthy adults, while Riazati et al. [[16](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref016)] reported favorable absolute reliability for gait parameters collected outside conventional motion-analysis laboratories using an MMC system. Collectively, these findings support the use of multi-camera MMC for gait analysis; however, such systems still require multiple synchronized cameras, dedicated capture volumes, and relatively fixed acquisition configurations. Single-camera MMC offers a potentially more accessible alternative to synchronized multi-camera systems. Conventional single-camera (RGB) video, a single camera provides two-dimensional image-plane information from which anatomical landmarks can be estimated using computer-vision-based pose-estimation methods. The resulting two-dimensional landmark trajectories can then be used to identify gait events and derive planar spatiotemporal measures without requiring multiple cameras or special markers. Prior studies have demonstrated the feasibility of this approach [[18](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref018),[19](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref019)]. Dunn et al. [[18](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref018)] validated a markerless single-camera system against marker-based three-dimensional motion analysis for walking and running, while Wang et al. [[19](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref019)] reported favorable agreement for most spatiotemporal gait parameters obtained from a single-camera computer-vision approach compared with marker-based multi-camera motion capture [[18](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref018),[19](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref019)]. Although benefits exist, reducing multi-camera three-dimensional reconstruction to a single two-dimensional view introduces additional methodological challenges. Measurements may be affected by camera position and orientation, perspective disorientation, image-plane assumptions, landmark-detection error, and reduced ability to quantify movement occurring outside the calibrated plane [[20](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363369#pone.0363369.ref020)]. Temporal measurement may also be influenced by video sa
## Related Clinical Research

- [Remibrutinib versus teriflunomide in relapsing multiple sclerosis: REMODEL-1 and REMODEL-2 phase 3](https://medichelpline.com/clinical-feed/pubmed-42915009.md) (DOI: 10.1016/S0140-6736(26)02058-1)
- [U.S. POINTER: Structured lifestyle program slows brain aging and cardiometabolic risk over 24 mont](https://medichelpline.com/clinical-feed/medical-news-today-0-combining-physical-mental-and-social-habits-slows-brain-aging-in-2-year-trial.md)
- [Developmental, cell-specific gene regulation linked to brain disorder mechanisms and targets](https://medichelpline.com/clinical-feed/biorxiv-6-brain-disorder-mechanisms-and-therapeutic-targets-identified-from-developmental.md)
- [Tongue–Jaw Timing Differences in ALS Versus Other Dysarthrias During [kai]](https://medichelpline.com/clinical-feed/medrxiv-2-inter-articulatory-timing-of-vocalic-tongue-body-and-jaw-movements-across.md)
- [Online MBCT for People with Multiple Sclerosis and Mild–Moderate Depression: Hybrid Trial Protocol](https://medichelpline.com/clinical-feed/plos-one-22-online-mindfulness-based-cognitive-therapy-for-people-with-multiple-sclerosis.md)

## Navigation
- [← Back to Neurology Feed](https://medichelpline.com/clinical-feed/neurology.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.