title: "Boundary-sensitive, structure-adaptive lightweight network for CT liver segmentation"
id: "plos-one-23-a-boundary-sensitive-and-structure-adaptive-lightweight-network-for-medical"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-23-a-boundary-sensitive-and-structure-adaptive-lightweight-network-for-medical"
content_type: "clinical_feed_article"
specialty: "Radiology"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363127"
published_at: "2026-11-20T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Boundary-sensitive, structure-adaptive lightweight network for CT liver segmentation
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-23-a-boundary-sensitive-and-structure-adaptive-lightweight-network-for-medical
- **Specialty:** [Radiology](https://medichelpline.com/clinical-feed/radiology.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363127)
- **Published At:** 2026-11-20T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- The authors developed a U-shaped segmentation framework integrating three targeted modules: **BSRA** (Boundary-Sensitive Semantic Recalibration Attention), **SASF** (Structure-Adaptive Scale Selection Fusion), and **DCRB** (Detail-Compensated Residual Lightweight Block). These were assembled to address ambiguous boundaries, scale heterogeneity, and lightweight-detail degradation. - Experiments used the CT subset of the CHAOS dataset with a patient-level five-fold cross-validation protocol; metrics were averaged per fold and then summarized across folds as reported by the authors. - Against a baseline U-Net, adding **BSRA** raised Dice from 0.8443 to 0.8492 and increased Boundary F1-score from 0.7728 to 0.8081; the Boundary F1 improvement reached significance in a paired Wilcoxon signed-rank test, while the Dice change did not. - Incorporating **SASF** produced the performance-oriented variant with best overall reported numbers: Dice 0.8929, IoU 0.8663, Boundary F1-score 0.8466, HD95 6.5729, ASSD 1.8947, as presented in the article. - Replacing heavy blocks with **DCRB** yielded a lightweight variant with Dice 0.8710, IoU 0.8463, and Boundary F1-score 0.8392 while reducing parameters from 14.70M to 2.47M and FLOPs from 31.81G to 8.44G. - Validation on the LiTS dataset reproduced the same overall performance trends reported on CHAOS, according to the authors; the source states code and scripts are available on GitHub and both datasets are publicly cited. - Reported evaluation combined overlap metrics (Dice, IoU, Precision, Recall), boundary-sensitive metrics (Boundary F1-score, HD95, ASSD) and complexity measures (parameter count, FLOPs, inference time) to characterize trade-offs between accuracy, boundary fidelity, and model compactness. - The authors noted no new raw data were generated, no specific funding, and no declared competing interests. The study did not report trial-level patient demographics, training hyperparameters, or inference latency details beyond the aggregated complexity indicators.
## Clinical Analysis & Structured Key Points
A boundary-sensitive and structure-adaptive lightweight network for medical image segmentation | PLOS One Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click here . Article Authors Metrics Comments Media Coverage Reader Comments Figures Figures Abstract Reliable medical image segmentation remains challenging in weak-contrast boundary regions, ambiguous anatomical transitions, and structurally heterogeneous areas. In addition, many high-performing models improve overlap-based metrics by introducing increasingly complex architectures, making it difficult to balance segmentation accuracy, boundary fidelity, and model compactness. To address these issues, this paper presents a boundary-sensitive and structure-adaptive lightweight framework for CT liver segmentation. The proposed method integrates three task-oriented components in a U-shaped architecture: Boundary-Sensitive Semantic Recalibration Attention (BSRA), Structure-Adaptive Scale Selection Fusion (SASF), and a Detail-Compensated Residual Lightweight Block (DCRB). Experiments were conducted on the CT subset of the CHAOS dataset under a patient-level five-fold cross-validation protocol. For each fold, metrics were first averaged across the corresponding test cases, and the reported values summarize the five fold-specific test means. Compared with the baseline U-Net, introducing BSRA increased Dice from 0.8443 to 0.8492 and improved Boundary F1-score from 0.7728 to 0.8081. The Boundary F1 improvement was statistically significant in the paired case-level Wilcoxon signed-rank test, whereas the Dice change was not significant, supporting the boundary-oriented role of BSRA. With the further incorporation of SASF, the performance-oriented variant achieved the best overall results, including a Dice coefficient of 0.8929, an Intersection over Union (IoU) of 0.8663, a Boundary F1-score of 0.8466, a 95% Hausdorff Distance (HD95) of 6.5729, and an Average Symmetric Surface Distance (ASSD) of 1.8947. After introducing DCRB, the lightweight variant still maintained competitive performance, attaining a Dice coefficient of 0.8710, an IoU of 0.8463, and a Boundary F1-score of 0.8392, while reducing the parameter count from 14.70M to 2.47M and the FLOPs from 31.81G to 8.44G. Additional validation on LiTS reproduced the same overall performance trends on a second liver CT dataset. These results show that the proposed framework improves region-level segmentation, boundary-level structural fidelity, and model compactness, providing a practical balance for CT liver segmentation. Citation: Guo Y, Liu Y, Ma S (2026) A boundary-sensitive and structure-adaptive lightweight network for medical image segmentation. PLoS One 21(11): e0363127. https://doi.org/10.1371/journal.pone.0363127 Editor: Xiaowei Li, Sichuan University, CHINA Received: May 21, 2026; Accepted: November 4, 2026; Published: November 20, 2026 Copyright: © 2026 Guo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: The datasets used in this study are publicly available and have been appropriately cited in the manuscript, including the CT subset of the CHAOS dataset and the Liver Tumor Segmentation Benchmark (LiTS) dataset. No new raw data were generated in this study. The source code and scripts required to reproduce the main results are publicly available at GitHub: https://github.com/xu-c22/imageseg . Funding: The author(s) received no specific funding for this work. Competing interests: The authors have declared that no competing interests exist. 1 Introduction Medical image segmentation is a fundamental task in medical image analysis and computer-aided clinical workflows, and has been widely studied for anatomical delineation, lesion analysis, treatment planning, and quantitative assessment because it provides precise structural information for downstream clinical decision-making [ 1 , 2 ]. Among various imaging modalities, computed tomography (CT) provides rich anatomical information and is extensively used in abdominal organ analysis and disease evaluation [ 3 , 4 ]. However, accurate medical image segmentation remains challenging in practice. First, organ boundaries in CT images are often ambiguous due to low contrast, partial volume effects, and intensity overlap between adjacent tissues. Second, the morphology, scale, and spatial distribution of target organs vary considerably across slices and patients, which makes it difficult for models based on fixed receptive fields to achieve robust segmentation. In addition, although many recent methods pursue higher segmentation accuracy through increasingly sophisticated architectures and stronger context modeling, such designs often introduce higher model complexity and computational cost, limiting their efficiency and practicality in real-world medical scenarios [ 5 , 6 ]. In recent years, deep learning-based segmentation methods, especially U-Net and its variants, have achieved remarkable progress in medical image segmentation. By integrating encoder-decoder architectures with skip connections, these methods significantly improve dense prediction performance and have become the dominant paradigm in this field [ 7 , 8 ]. Nevertheless, many existing studies mainly focus on improving average overlap metrics such as Dice coefficient and Intersection over Union (IoU), while paying insufficient attention to several issues that are particularly critical from the medical perspective. On the one hand, blurred boundaries, semantically confusable transition regions, and structurally complex local areas are still difficult to segment accurately. On the other hand, many methods enhance performance by introducing increasingly complex modules, but the resulting models are often computationally expensive and less suitable for efficient deployment [ 9 , 10 ]. Therefore, how to design a segmentation network that not only improves the representation of ambiguous boundary regions and scale-sensitive structures, but also maintains a lightweight and efficient architecture, remains an important yet insufficiently explored problem. To address these issues, this paper proposes a boundary-sensitive and structure-adaptive lightweight network for medical image segmentation. The proposed framework is developed around three problem-oriented designs. First, a Boundary-Sensitive Semantic Recalibration Attention (BSRA) module is introduced at the bottleneck stage to enhance deep semantic channels that are more informative for ambiguous boundary delineation and organ discrimination. Different from generic channel attention mechanisms, BSRA jointly models global semantic importance and boundary-sensitive local variation, thereby improving the network’s response to difficult regions with unclear anatomical transitions. Second, a Structure-Adaptive Scale Selection Fusion (SASF) module is designed to capture heterogeneous contextual dependencies through multiple receptive-field branches and to adaptively reweight their contributions according to structural characteristics. In this way, the model can better handle scale-sensitive regions and shape-varying structures. Third, to alleviate the detail degradation commonly caused by lightweight convolutions, a Detail-Compensated Residual Lightweight Block (DCRB) is constructed to preserve local continuity and boundary-sensitive information while reducing parameter redundancy and computational burden. Through the coordinated integration of these three components, the proposed method aims to improve segmentation quality from the perspective of boundary representation, scale adaptation, and practical efficiency, rather than merely pursuing global average metric gains. Experiments were conducted on CT liver segmentation tasks to evaluate the proposed method from three complementary aspects: overall segmentation accuracy, boundary quality, and model efficiency. In addition to conventional overlap-based metrics such as Dice coefficient, Intersection over Union (IoU), Precision, and Recall, boundary-sensitive metrics including Boundary F1-score, 95% Hausdorff Distance (HD95), and Average Symmetric Surface Distance (ASSD) were adopted to provide a more comprehensive assessment of segmentation performance in clinically challenging regions. Model complexity indicators, including parameter count, floating-point operations (FLOPs), and inference time, were also reported to evaluate the lightweight advantage and practical trade-off of the proposed framework. The main contributions of this paper can be summarized as follows: A Boundary-Sensitive Semantic Recalibration Attention (BSRA) module is proposed to enhance deep semantic channels that are more relevant to ambiguous boundary regions and semantically confusable anatomical structures. A Structure-Adaptive Scale Selection Fusion (SASF) module is designed to dynamically regulate the importance of different receptive-field branches, thereby improving the representation of scale-sensitive and structurally complex regions. A Detail-Compensated Residual Lightweight Block (DCRB) is developed to reduce model redundancy while preserving local continuity and boundary-sensitive detail information. A boundary-sensitive and structure-adaptive lightweight segmentation framework is constructed, which aims to improve not only overall segmentation accuracy but also boundary quality and practical efficiency in medical image segmentation tasks. 2 Related work Deep learning has substantially advanced medical image segmentation in recent years, especially through the development of U-shaped encoder-decoder architectures, attention-based feature enhancement, multi-scale context modeling, and lightweight network design [ 1 , 2 ]. These research directions have provided effective solutions for improving segmentation accuracy under challenging conditions. However, for medical image segmentation tasks, especially organ segmentation in CT images, several practically important issues remain insufficiently addressed, including ambiguous boundaries, semantically confusable transition regions, heterogeneous scale demands, and the trade-off between segmentation performance and computational efficiency [ 5 , 6 , 10 ]. This section reviews representative studies from four aspects: U-shaped segmentation networks, boundary-aware and attention-guided segmentation, multi-scale context modeling, and lightweight medical image segmentation, thereby providing the technical foundation and research motivation for this work. 2.1 U-shaped medical image segmentation networks U-shaped encoder-decoder networks have remained one of the dominant architectural paradigms in medical image segmentation [ 2 ]. Following the success of early fully convolutional designs, subsequent studies have improved this framework from different perspectives, including volumetric representation, recursive residual learning, stacked encoder-decoder design, channel-wise interaction, and hybrid CNN-transformer modeling. For example, V-Net extended the encoder-decoder formulation to volumetric medical image segmentation and demonstrated the effectiveness of end-to-end dense prediction in 3D settings [ 11 ]. R2U-Net incorporated recurrent residual units into the U-shaped framework to enhance feature reuse and representation capacity [ 12 ], while DoubleU-Net adopted a cascaded dual U-Net design to progressively refine segmentation results [ 13 ]. ResUNet++ introduced residual connections and multi-scale feature enhancement into the U-shaped backbone, showing that structural refinement of convolutional blocks can improve segmentation robustness [ 14 ]. More recently, research on U-shaped architectures has moved beyond conventional convolution-only designs and increasingly incorporated transformer-based or hybrid modeling strategies. Swin-U-Net, UCTransNet, UTNet, nnFormer, MISSFormer, and TransBTS demonstrated the value of long-range dependency modeling and stronger cross-scale interaction in medical segmentation [ 15 – 20 ]. However, these general-purpose or volumetric improvements do not directly resolve the low-contrast boundary ambiguity and efficiency constraints encountered in CT liver segmentation. This motivates a more problem-driven design that explicitly aligns attention, scale selection, and lightweight feature extraction with the practical bottlenecks of CT organ delineation. 2.2 Boundary-aware and attention-guided segmentation Although many medical image segmentation models report strong overlap-based performance, boundary ambiguity remains a persistent challenge in practical applications. Recent studies have increasingly incorporated explicit boundary modeling into segmentation frameworks, including boundary-aware fusion, boundary supervision, gradient-based contour modeling, boundary filtering, uncertainty-aware perception, and joint boundary-global context learning [ 21 – 28 ]. These methods show that boundary-sensitive representation is important beyond conventional region-overlap optimization. A representative example is the end-to-end boundary-aware network of Hatamizadeh et al. [ 10 ], which introduces an explicit edge branch and edge-aware objectives; this method is therefore included in our main experimental comparison as a boundary-aware baseline. However, many boundary-aware methods rely on extra boundary supervision, explicit gradient maps, or task-specific auxiliary branches, which may increase training complexity or sensitivity to noisy contours. The proposed BSRA instead performs boundary-sensitive semantic recalibration at the bottleneck stage by jointly modeling global semantic responses and local structural variation, without requiring an additional boundary label. 2.3 Multi-scale context modeling Another important research direction is multi-scale context modeling. This is particularly relevant in medical image segmentation because anatomical structures may vary substantially in shape, scale, and local topology across patients and image slices. Early studies on contextual representation mainly originated from general semantic segmentation. For example, DeepLabv3 + combined atrous spatial pyramid pooling with an encoder-decoder design to refine segmentation results [ 29 ], DenseASPP further enhanced receptive-field diversity through densely connected atrous convolutions [ 30 ], and FPN introduced a top-down feature pyramid fusion strategy that has strongly influenced later dense prediction models [ 31 ]. These studies established the general importance of multi-scale context aggregation for pixel-wise prediction. In medical image segmentation, multi-scale context modeling has been further adapted to better capture anatomical structures with highly variable appearance. KiU-Net proposed an overcomplete branch to preserve fine-grained structures while complementing the conventional U-shaped pathway [ 32 ]. CPFNet further designed a context pyramid fusion strategy to combine global and multi-scale contextual information more effectively [ 33 ]. More recent studies continued to strengthen this line. For instance, a UNet-based multi-scale context fusion method explicitly assigned different weights to semantic features from different encoding stages [ 34 ], while a multi-scale cross-fusion medical image segmentation network based on a dual-attention transformer showed that multi-scale context fusion can also be enhanced by attention-guided interaction mechanisms [ 35 ]. 2.4 Lightweight medical image segmentation Besides segmentation accuracy, model efficiency has become increasingly important in medical image analysis. Many high-performing segmentation networks rely on deeper backbones, heavier feature fusion modules, or more complicated attention mechanisms, which may improve benchmark performance but also increase computational burden and deployment difficulty [ 36 – 40 ]. To alleviate this issue, lightweight medical image segmentation has gradually become an active research topic. For example, UNeXt reformulated the segmentation backbone with an MLP-based rapid architecture and showed that efficient design can still achieve competitive medical segmentation performance [ 36 ]. LCMUNet further combined CNN and MLP modules for real-time medical image segmentation, emphasizing the balance among accuracy, parameter size, and computational efficiency [ 37 ]. GA-UNet introduced a lightweight Ghost-and-Attention U-Net framework to improve feature extraction efficiency under a compact design [ 38 ], while LV-UNet explored a lightweight and vanilla segmentation architecture under a simplified design philosophy [ 39 ]. More recent studies have continued to strengthen this line. LUCF-Net proposed a lightweight U-shaped cascade fusion architecture for medical image segmentation [ 40 ]. Meanwhile, lightweight U-Net with depthwise separable convolution demonstrated that replacing standard convolutions with more efficient depthwise separable operations can substantially reduce computational redundancy while maintaining segmentation capability [ 41 ]. In addition, LIU-NET introduced a lightweight Inception U-Net framework for efficient brain tumor segmentation from multimodal 3D MRI images [ 42 ]. Although these methods are developed under different application scenarios, they consistently indicate that lightweight segmentation has evolved from simple model compression into a more systematic research direction, where architectural redesign is explicitly used to balance efficiency and segmentation quality. In summary, prior studies have made substantial progress from three major directions: attention-guided feature enhancement, multi-scale context representation, and lightweight architectural optimization. Nevertheless, these directions are often explored independently, and their designs are not always explicitly aligned with three closely coupled issues that are especially important in CT organ segmentation: insufficient emphasis on ambiguous boundary regions, inadequate adaptation to heterogeneous scale demands, and local detail degradation caused by lightweight modeling. Motivated by these observations, this work aims to construct a problem-driven framework in which boundary-sensitive semantic recalibration, structure-adaptive scale selection, and detail-compensated lightweight feature extraction are integrated into a unified segmentation network. 3 Method 3.1 Overall architecture Medical image segmentation, especially organ segmentation in CT images, faces three tightly coupled challenges: ambiguous anatomical boundaries, heterogeneous scale demands across different regions, and the degradation of local structural details under lightweight modeling. To address these issues in a unified framework, this paper proposes a Boundary-Sensitive and Structure-Adaptive Lightweight Segmentation Network, which is built upon a U-shaped encoder-decoder architecture and enhanced by three problem-driven modules, namely Boundary-Sensitive Semantic Recalibration Attention (BSRA), Structure-Adaptive Scale Selection Fusion (SASF), and Detail-Compensated Residual Lightweight Block (DCRB). Different from conventional improvement strategies that mainly stack generic encoder-decoder refinements, recurrent residual units, or hybrid CNN-transformer modules for higher average overlap scores [ 12 , 13 , 17 ], the proposed framework is designed from the perspective of the actual bottlenecks in CT liver segmentation. Specifically, the initial image-level stem employs DCRB to extract shallow features, and the subsequent encoder and decoder stages continue to use DCRB as the primary lightweight feature extraction unit. DCRB is paired with MaxPool operations in the encoder and Upsample operations in the decoder to realiz
## Related Clinical Research

- [NHS launches world’s largest AI-assisted breast screening trial in England](https://medichelpline.com/clinical-feed/bmj-0-world-x2019-s-largest-ai-assisted-breast-screening-trial-begins-in-england.md)
- [3D Montage Cryo-ET Maps Heterogeneous Lamellipodial Actin Networks](https://medichelpline.com/clinical-feed/biorxiv-20-large-scale-3d-stitching-montage-cryo-electron-tomography-reveals-heterogeneity.md)
- [Optimizing PALM imaging of the nuclear pore complex with mEos4b: oxygen and buffer effects](https://medichelpline.com/clinical-feed/biorxiv-2-optimizing-environmental-conditions-for-palm-imaging-of-the-nuclear-pore.md)
- [Automated aortoiliac calcification segmentation from arterial-phase CT: development and validation](https://medichelpline.com/clinical-feed/medrxiv-0-automated-aortoiliac-calcification-segmentation-from-arterial-phase-computed.md)
- [Microcirculation Mirror: Browser-based workstation for hand microvasculature and nailfold capillar](https://medichelpline.com/clinical-feed/medrxiv-27-microcirculation-mirror-a-zero-install-browser-workstation-for-hand.md)

## Navigation
- [← Back to Radiology Feed](https://medichelpline.com/clinical-feed/radiology.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.