title: "Microcirculation Mirror: Browser-based workstation for hand microvasculature and nailfold capillar"
id: "medrxiv-27-microcirculation-mirror-a-zero-install-browser-workstation-for-hand"
canonical_url: "https://medichelpline.com/clinical-feed/medrxiv-27-microcirculation-mirror-a-zero-install-browser-workstation-for-hand"
content_type: "clinical_feed_article"
specialty: "Radiology"
source_name: "medRxiv (Clinical Preprints)"
source_url: "https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1?rss=1"
published_at: "2026-11-17T12:00:00.000Z"
evidence_level: "Verified Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Microcirculation Mirror: Browser-based workstation for hand microvasculature and nailfold capillar
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/medrxiv-27-microcirculation-mirror-a-zero-install-browser-workstation-for-hand
- **Specialty:** [Radiology](https://medichelpline.com/clinical-feed/radiology.md)
- **Primary Source:** medRxiv (Clinical Preprints)
- **Source URL:** [Original Journal Publication](https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1?rss=1)
- **Published At:** 2026-11-17T12:00:00.000Z
- **Evidence Rating:** Verified Feed
## Executive GIST (TL;DR)
- The team developed **Microcirculation Mirror**, a single-file, zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator. - The application runs offline on a laptop and, over local HTTPS, can function on a phone as an installable app; the authors reported no patient data were used. - The 3D atlas holds 136 named structures per hand drawn from open Z-Anatomy/BodyParts3D meshes and includes a literature-parameterized capillary layer. - The NVC module renders a 200×, 1.2-mm field and produces six deterministic capillary patterns with quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. - A lumped microcirculatory model provides nine estimates (SIM); an imaging-physics module quantifies detector sampling effects and contrast limits. - Imaging-physics results: a 10-μm **capillary** occupies 0.07 of a 150-μm detector pixel; iodinated contrast yields ≈0.016% effective contrast, about 60× below a 1% detection threshold; unenhanced blood contrast is ≈270× lower. - Rendering performance: the 2D stage renders in 2.9 ms per frame, and system merging reduces atlas draw calls from 136 to 6, improving runtime efficiency. - The authors framed the tool as a reproducible prototype for multi-scale microvascular reasoning; they stated explicitly that the instrument is a product prototype and not a medical device. - All data from the study are available on reasonable request to the authors; the source declares adherence to ethical guidelines and no competing interests.
## Clinical Analysis & Structured Key Points
Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy | medRxiv Skip to main content Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy View ORCID Profile Yingyu Wang , View ORCID Profile Jingjing He , View ORCID Profile Weiqi Liu , View ORCID Profile Xiang Xu , View ORCID Profile Bingwei Li , View ORCID Profile Yuan Li , View ORCID Profile Bing Wang , View ORCID Profile Mingming Liu doi: https://doi.org/10.64898/2026.11.15.26368085 Yingyu Wang 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Yingyu Wang Jingjing He 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Jingjing He Weiqi Liu 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Weiqi Liu Xiang Xu 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Xiang Xu Bingwei Li 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Bingwei Li Yuan Li 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Yuan Li Bing Wang 1 Institute of Microcirculation, Chinese Academy of Medical Sciences & Peking Union Medical College; Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Bing Wang Mingming Liu 2 Chinese Academy of Medical Sciences & Peking Union Medical College Find this author on Google Scholar Find this author on PubMed Search for this author on this site ORCID record for Mingming Liu For correspondence: mingmingliu{at}imc.pumc.edu.cn Abstract Info/History Metrics Supplementary material Data/Code Preview PDF Abstract Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 μm lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200×, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-μm capillary occupies 0.07 of a 150-μm detector pixel; with iodinated contrast it retains ≈0.016% effective contrast, about 60× below a 1% detection threshold; unenhanced blood is ≈270× lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible. Competing Interest Statement The authors have declared no competing interest. Author Declarations I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained. Yes I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals. Yes I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance). Yes I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable. Yes Data Availability All data produced in the present study are available upon reasonable request to the authors Funder Information Declared Beijing Municipal Natural Science Foundation , 7252093 Copyright The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC 4.0 International license . Back to top Previous Next Posted November 17, 2026. Download PDF Supplementary Material Data/Code Email Thank you for your interest in spreading the word about medRxiv. NOTE: Your email address is requested solely to identify you as the sender of this article. Your Email * Your Name * Send To * Enter multiple addresses on separate lines or separate them with commas. You are going to email the following Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy Message Subject (Your Name) has forwarded a page to you from medRxiv Message Body (Your Name) thought you would like to see this page from the medRxiv website. Your Personal Message CAPTCHA This question is for testing whether or not you are a human visitor and to prevent automated spam submissions. Share Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy Yingyu Wang , Jingjing He , Weiqi Liu , Xiang Xu , Bingwei Li , Yuan Li , Bing Wang , Mingming Liu medRxiv 2026.11.15.26368085; doi: https://doi.org/10.64898/2026.11.15.26368085 Share This Article: Copy Citation Tools Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy Yingyu Wang , Jingjing He , Weiqi Liu , Xiang Xu , Bingwei Li , Yuan Li , Bing Wang , Mingming Liu medRxiv 2026.11.15.26368085; doi: https://doi.org/10.64898/2026.11.15.26368085 Citation Manager Formats BibTeX Bookends EasyBib EndNote (tagged) EndNote 8 (xml) Medlars Mendeley Papers RefWorks Tagged Ref Manager RIS Zotero Tweet Widget Facebook Like Google Plus One Subject Areas All Articles Addiction Medicine (642) Allergy and Immunology (925) Anesthesia (355) Cardiovascular Medicine (5043) Dentistry and Oral Medicine (496) Dermatology (431) Emergency Medicine (681) Endocrinology (including Diabetes Mellitus and Metabolic Disease) (1702) Epidemiology (16325) Forensic Medicine (36) Gastroenterology (1245) Genetic and Genomic Medicine (7312) Geriatric Medicine (758) Health Economics (1099) Health Informatics (5327) Health Policy (1479) Health Systems and Quality Improvement (1844) Hematology (600) HIV/AIDS (1386) Infectious Diseases (except HIV/AIDS) (16520) Intensive Care and Critical Care Medicine (1206) Medical Education (702) Medical Ethics (157) Nephrology (755) Neurology (7644) Nursing (380) Nutrition (1138) Obstetrics and Gynecology (1302) Occupational and Environmental Health (1045) Oncology (3758) Ophthalmology (1101) Orthopedics (413) Otolaryngology (470) Pain Medicine (506) Palliative Medicine (144) Pathology (724) Pediatrics (1872) Pharmacology and Therapeutics (758) Primary Care Research (789) Psychiatry and Clinical Psychology (6169) Public and Global Health (10035) Radiology and Imaging (2550) Rehabilitation Medicine and Physical Therapy (1533) Respiratory Medicine (1277) Rheumatology (663) Sexual and Reproductive Health (811) Sports Medicine (601) Surgery (807) Toxicology (109) Transplantation (320) Urology (309)
## Related Clinical Research

- [High saturated fat intake and LDL cholesterol in people with genetic risk](https://medichelpline.com/clinical-feed/medical-news-today-0-high-saturated-fat-intake-may-spike-ldl-cholesterol-in-people-with-genetic-risk.md)
- [Diabetes Care at ENDO 2026: From Pregnancy Through Transplant and Training](https://medichelpline.com/clinical-feed/endocrine-news-0-diabetes-care-advancing-the-science-seeing-the-person.md)
- [Kymera mid-stage success raises prospect of a Dupixent rival in eczema](https://medichelpline.com/clinical-feed/stat-news-0-stat-a-big-win-for-a-potential-competitor-for-dupixent-eczema-treatment.md)
- [FDA Rejects Capricor’s Duchenne Drug; Lilly Buys LoQus23; Kymera Reports Phase 2 Eczema Success](https://medichelpline.com/clinical-feed/stat-news-1-stat-pharmalittle-we-re-reading-about-capricor-s-duchenne-drug-lilly-s-15th.md)
- [Intravenous Inotropes and 30-Day Mortality in Takotsubo Syndrome — SWEDEHEART Cohort](https://medichelpline.com/clinical-feed/medrxiv-11-intravenous-inotropes-and-mortality-in-takotsubo-syndrome-a-nationwide-cohort.md)

## Navigation
- [← Back to Radiology Feed](https://medichelpline.com/clinical-feed/radiology.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.