title: "Skin swab multi-omic profiling to monitor radiation exposure"
id: "plos-one-21-monitoring-radiation-exposure-through-skin-swab-multi-omic-profiling"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-21-monitoring-radiation-exposure-through-skin-swab-multi-omic-profiling"
content_type: "clinical_feed_article"
specialty: "Radiology"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0354734"
published_at: "2026-08-05T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Skin swab multi-omic profiling to monitor radiation exposure
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-21-monitoring-radiation-exposure-through-skin-swab-multi-omic-profiling
- **Specialty:** [Radiology](https://medichelpline.com/clinical-feed/radiology.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0354734)
- **Published At:** 2026-08-05T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- The study evaluated non-invasive **skin swab** multi-omic profiling as a biodosimetry strategy to detect ionizing radiation exposure and dose-specific responses. - Models used were colonized human skin equivalents (coHSE) with groups exposed to 0, 1, or 4 Gy of x-rays (0 Gy n = 8, 1 Gy n = 6, 4 Gy n = 6) and mice (n = 6 per group). - Analyses integrated **metabolomics**, **lipidomics**, and **metagenomics** on skin swab samples collected after exposure to identify molecular and microbial signatures. - Two distinct metabolite panels were reported: one that discriminated irradiated from non-irradiated skin, and another that distinguished dose-specific responses. - Conserved radiation-responsive metabolites included **uric acid**, **xanthine**, and **taurine**; skin-specific markers associated with barrier integrity included **proline** and **arginine**. - Lipid analysis showed diacylglycerol network enrichment consistent with a repair-driven molecular response. - Metagenomic shifts included changes in radioprotective microbial taxa such as **Lachnospiraceae** and **Lactobacillales**, supporting microbial contributions to the response. - Authors conclude that skin swab signatures are feasible for non-invasive exposure classification and provide a molecular and microbial framework for developing skin-based biodosimetry tools. - The paper recommends validation in human cohorts for real-world biodosimetry applications; raw 16S rRNA sequencing data are available in NCBI BioProject PRJNA1308618 and supporting data through ImmPort study SDY3652. - Funding sources and institutional acknowledgments were reported; no competing interests were declared by the authors.
## Clinical Analysis & Structured Key Points
Monitoring radiation exposure through skin swab multi-omic profiling | PLOS One Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click here . Article Authors Metrics Comments Media Coverage Peer Review Reader Comments Figures Figures Abstract Exposure to ionizing radiation poses major health risks across medical, occupational, and spaceflight settings, driving the need for rapid, non-invasive biodosimetry tools. As the body’s most accessible organ and the most frequent site of radiation injury, the skin represents a promising interface for monitoring exposure. Using colonized human skin equivalents (coHSE; 0 Gy n = 8, 1 Gy n = 6, 4 Gy n = 6) and mice (n = 6/group) models, we performed multi-omic profiling, integrating metabolomics, lipidomics, and metagenomics, on skin swab samples collected after exposure to 0, 1, or 4 Gy of x-rays. We identified two distinct metabolite panels: one discriminating irradiated from non-irradiated skin, and another distinguishing dose-specific response. These panels included conserved radiation-responsive metabolites (e.g., uric acid, xanthine, taurine) and skin-specific markers associated with barrier integrity (e.g., proline, arginine). Diacylglycerol network enrichment and shifts in radioprotective microbial taxa, including Lachnospiraceae and Lactobacillales, further supported a repair-driven molecular response. These data support the feasibility of skin swab signatures for non-invasive exposure classification, providing a molecular and microbial framework for skin based monitoring measure development and motivating validation in human cohorts for real-world biodosimetry. Citation: Vitry G, Angdisen J, Arriaga P, Irgen-Gioro S, Sawant MA, Vuong DC, et al. (2026) Monitoring radiation exposure through skin swab multi-omic profiling. PLoS One 21(8): e0354734. https://doi.org/10.1371/journal.pone.0354734 Editor: Yi Cao, Xiangtan University, CHINA Received: December 5, 2025; Accepted: July 11, 2026; Published: August 5, 2026 Copyright: © 2026 Vitry et al. This is an open access article distributed under the terms of the Creative Commons Attribution License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: Raw 16 S rRNA sequencing data have been deposited in the NCBI Sequence Read Archive under accession number [PRJNA1308618] and are available at . Data supporting this publication are also available through ImmPort ( https://www.immport.org ) under study SDY3652. Funding: This research was supported by the Intelligence Advanced Research Projects Activity (IARPA) TEI-REX program through the Army Research Office contract No.W911NF-22-C-0064 (P.I. Karyn Apfeldorf). Animal procedures realized at Lawrence Berkeley National Laboratory were supported by the IARPA TEI-REX contract number 20008-D2021-2107310008. The views and conclusions contained should not be interpreted as necessarily representing the official policies, either expressed or implied, of ODNI, IARPA, ARO, or the U.S. Government. The U.S. Government is authorized to reproduce and distribute reprints for governmental purposes notwithstanding any copyright annotation therein. The project described above was also supported by award no. P30 CA051008 (P.I. Louis Weiner) from the National Cancer Institute (NCI) and the National Institute of Allergy and Infectious Diseases (NIAID) award no. U01AI148307 (P.I.’s Evagelia C. Laiakis and Frederic Zenhausern). The content is solely the responsibility of the authors and does not necessarily represent the official views of the NCI or the NIH. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Competing interests: The authors have declared that no competing interests exist. Introduction Since the discovery of radioactivity in the late 19th century, the use of radiation across various domains, such as nuclear energy, medical diagnostics, and cancer therapy, has led to a steady increase in human exposure to ionizing radiation (IR). Accidental releases, reactor failures, and radiological incidents, whether unintentional or deliberate, have underscored the need for rapid radiation dose assessment. Events such as the Chernobyl and Fukushima-Daiichi nuclear accidents, or localized contamination episodes like Goiânia in Brazil, illustrate how technical, natural, or human factors can cause lasting radiological, biological, and environmental consequences [ 1 , 2 ]. In parallel, concerns about the potential use of radiological dispersal or improvised nuclear devices in populated areas highlight the urgency of developing scalable biodosimetry strategies for diverse exposure scenarios. Meanwhile, expanding aeronautics and space activities expose individuals to cosmic radiation, with nuclear-powered propulsion systems, key enabling technologies to future planetary exploration, representing an additional source of radiation in the coming decades [ 3 – 6 ]. IR elicits a wide spectrum of biological effects, from transient cellular stress to irreversible tissue damage, organ failure, and death, depending on dose, dose rate, and radiation quality. Accordingly, the development of rapid and reliable biodosimetry capable of estimating absorbed dose through biological markers has become critical to radiological emergency response, occupational safety, and personalized medicine. However, current biodosimetry approaches face critical limitations in scalability, accessibility, and time to result. According to the Biomedical Advanced Research and Development Authority (BARDA) recommendations, biodosimetry results should ideally be available in less than 15 min and cover a dose range of 0.5–10 Gy [ 4 ]. The gold standard approaches include cytogenetic techniques such as dicentric chromosome analysis and the cytokinesis-block micronucleus assay (CBMN). Theses assays, while highly accurate, involve labor-intensive, time-consuming techniques that typically require specialized laboratory infrastructure and several days to generate results, limiting their utility for rapid triage and field deployment during large-scale exposure events. Furthermore, these approaches also provide limited phenotypic insight that could guide preventive or therapeutic countermeasures. Similarly, alternative blood-based molecular and protein biomarkers methods, such as lymphocyte depletion kinetics via complete blood count (CBC), premature chromosome condensation (PCC), γ-H2AX foci formation, and physical dosimetry using Electron Paramagnetic Resonance (EPR) and Optically Stimulated Luminescence (OSL) of the teeth, require invasive sampling and may not be readily deployable for large-scale or longitudinal monitoring [ 6 – 17 ]. Therefore, there is an unmet need to develop alternative non-invasive biodosimetry approaches rapidly deployable, scalable, and capable of reflecting not only radiation dose but also biological response trajectories Based on mass spectrometry, metabolomic analyses enable the rapid identification and the measurement of all small molecules of 2 Gy), cutaneous radiation syndrome (CRS) occurs in 20–50% of individuals [ 25 ], with symptoms ranging from erythema and blistering to necrosis [ 26 – 29 ]. Importantly, the severity of cutaneous injury is formally recognized as a prognostic indicator by the IAEA, WHO, and U.S. REMM [ 30 – 32 ] correlating with total absorbed dose and systemic outcomes such as hematopoietic failure and multi-organ dysfunction, is incorporated into the Medical Treatment Protocols for Radiation Accident (METREPOL) consensus for clinical grading of irradiated victims and outcome prediction [ 33 ]. In addition, the skin microbiota are highly sensitive to environmental conditions, and alterations in the skin microbiome have been shown to reflect various clinical outcomes including wound healing and recovery from radiation-induced dermatitis [ 34 – 40 ]. We recently demonstrated that skin swabs collected from bioengineered human skin equivalents colonized with natural microbial communities and the mouse skin displayed similar taxonomic and metabolomic features in response to radiation exposure [ 41 ]. Operationally simple, skin swabs offer a minimally invasive, low training-burden sampling strategy compatible with diverse analytic platforms that can be repeated frequently, enabling longitudinal assessment. Unlike many biofluid-based approaches, swabs capture responses at a highly accessible and most directly exposed tissue interface and simultaneously measure host metabolites/lipids and microbiome shifts, enabling multi-layered signatures for exposure assessment. In the effort of developing simple, non-invasive skin-based biodosimetry method, the objective of this study was to evaluate the skin as a novel, accessible, and biologically informative tissue for radiation biodosimetry by characterizing dose-dependent molecular and microbial signatures following IR in skin swab samples. We hypothesized that the skin harbors conserved and functionally relevant alterations in metabolites, lipids, and microbial taxa that can reflect radiation dose and potentially reveal insights into systemic health outcomes. To test this hypothesis, we conducted a multi-omics analysis integrating metabolomics, lipidomics, and 16S rRNA-based microbiome profiling using skin swab samples collected from mouse models exposed to 0, 1, or 4 Gy of total body irradiation. These radiation doses were selected to reflect exposure levels relevant to radiation emergency scenarios, spanning a biologically and clinically relevant range recognized in biodosimetry frameworks. This dose interval enables evaluation of dose-dependent molecular responses and assessment of the capacity of skin-based multi-omic profiling to detect and discriminate radiation exposure under realistic and translationally relevant photon exposure conditions. To assess translational relevance and conservation of response, complementary analyses were also performed on full-thickness bioengineered human skin equivalents colonized with natural skin microbial communities from human donors (coHSE) and subjected to the same radiation doses. Multivariate statistics, pathway enrichment, and correlation analyses using the R mixOmics DIABLO framework, a supervised multiblock integration method using sparsity constraints (sparse partial least square differential analysis, sPLS-DA) for identifying correlated and discriminative features across omics datasets, were employed to identify radiation-responsive features, and overlap with previously reported radioresponsive molecular and microbial biomarkers. In particular, DIABLO enables integration of multi-omic datasets and identification of correlated biomarker panels. To balance exploratory multi-omic feature discovery with assessment of generalizability, we implemented a two-stage analytical design in which DIABLO was used to identify candidate radiation-responsive features in a discovery cohort, followed by independent validation of these signatures in a separate mouse cohort not used for feature selection or model fitting. Given the importance of natural moisturizing factor (NMF) on skin hydration and barrier function, we assessed the dose responsiveness of its key components including lactic acid, urea, pyrrolidone carboxylic acid (PCA), urocanic acid (UCA), and byproducts of filaggrin degradation (e.g., serine, glycine, alanine, histidine, arginine, glutamic acid, aspartic acid, threonine, proline). Materials and methods Human skin equivalents Commercially available full-thickness human skin equivalents (HSE) were obtained from Labskin (Deepverge, UK). The production method of this model can be found in Holland et al., 2008 [ 42 ]. HSEs were shipped at day 12 of air-liquid interface maturation (day ALI 12) in semi-solid media and equilibrated overnight at 37°C and 5% CO 2 in 12-well plates containing 1 mL of maintenance medium upon reception. The day after arrival, HSE were inoculated with natural skin microbiota isolated from healthy adult volunteer recruited by American Type Culture Collection (ATCC) under IRB-approved protocol (Pro00067707). Skin microbial communities were collected from both cheeks of 38 donors using a scrub-wash method (ATCC protocol) [ 43 ], and pooled to increase colony-forming unit (CFU) yields. HSEs were colonized using human skin microbiome samples collected from human donors, as previously described [ 44 ], with varied age, sex, and ethnicity ensuring representative diversity. To ensure that colonized HSE (coHSE) reflected representative human skin microbial diversity while maintaining donor-level biological variability, colonization was performed using microbiome samples derived from 11 independent human donors resulting in 20 total inoculations distributed across experimental radiation dose groups (0 Gy: n = 8; 1 Gy: n = 6; 4 Gy: n = 6). Each experimental condition included microbiomes from multiple donors, and several donors contributed samples across different dose groups, reducing potential donor-specific bias (Supplemental S1 Table ). The donor cohort included both female (63.6%) and male (36.4%) participants and spanned two adult age ranges (20–40 years: 36.4%; 40–60 years: 63.6%) (Supplemental S1 Table ). Although females were more represented overall and male donors were primarily represented in the younger age group, inclusion of multiple independent donors per condition ensured that results were not driven by a single donor or demographic subgroup. Pooled microbial suspensions were washed with sterile deionized water and centrifuged twice to remove detergents and debris. Each HSE was inoculated with 10 µL of microbial suspension (at 1x10 6 CFU/mL which translates to 1x10 4 CFU/cm 2 ) one day before irradiation (at day 14 of HSE maturation). A slightly larger sham group was included in the coHSE model to improve characterization of baseline variability inherent to human-derived microbial communities and to provide a robust reference for downstream comparative and integrative analyses. The next day, coHSEs were exposed to x-rays at 0 Gy (n = 8), 1 Gy (n = 6), or 4 Gy (n = 6), 24h after inoculation, in a XRAD 320 irradiator (320 kVp, 12.5 mA) fitted with a beam-conditioning filter (0.75 mm Tin + 0.25 mm Copper + 1.5 mm Aluminum) providing a specific beam Half Value Layer (HVL) of ≅ 4 mm Cu at 50 cm from the source. The dose rate was 0.85 Gy/min and dosimetry was performed using a NIST-traceable ionization chamber (Radcal 10x6-6, Monrovia CA) calibrated to air kerma. This irradiation system operates within established X-ray range for in vitro radiation biology and skin irradiation studies. Delivered dose was verified using NIST-traceable dosimetry, ensuring accurate and reproducible absorbed dose (Gy), the biologically relevant parameter reflecting energy deposition in tissue. Swab sample collection was standardized and consisted of 10 gentle rounds over the surface of each HSE construct for a time duration of 10 seconds. Swab samples were collected at 1, 3, and 7 days post-irradiation, snap frozen in liquid nitrogen and stored at −80˚C in 1.5 mL tubes until further processing. Animal procedures All animal procedures were approved by the Lawrence Berkeley National Laboratory IACUC (Protocol #270036, OLAW Assurance D16-0031/A3054-01). Male and female C57BL/6J mice (9–11 weeks old) were obtained from Jackson Laboratories and acclimated for two weeks before radiation exposure. Serving as a discovery cohort (see “ Statistical analysis” description section below): mice were randomly assigned to dose groups with equal sex repartition: 0 Gy (sham, n = 6), 1 Gy (n = 6), and 4 Gy (n = 6), and underwent total body irradiation, placed on a rotating platform (4 RPM) at 50 cm from the source, in a XRAD 320 irradiator (300 keV/10mA) fitted with a 0.5 mm Cu filter (HVL ≅ 1.7 mm Cu), at a dose rate of 1.3 Gy/min. Dosimetry was performed using a RadCal ionization chamber (Radcal 10X6-0.18) and gafchromic film. This system also operates within appropriate X-ray voltage ranges for small animal irradiation and skin radiation studies. Differences in filtration and dose rate reflect facility-specific equipment configurations. However, in both experimental systems, delivered dose was verified using NIST-traceable dosimetry, ensuring accurate and reproducible absorbed dose (Gy), thereby enabling valid comparison of dose-dependent biological responses across models. Skin swabs were collected from a 1.5 × 6 cm area on the dorsal skin, which was shaved at least 24 hours prior to irradiation to allow initial microbial recovery, with a minimum of 48 hours between shaving and the first post-irradiation sample collection at 1, 3, and 7 days. The timing of shaving was prospectively optimized during experimental planning and incorporated into a standardized operational procedure to minimize transient perturbations of the skin barrier and microbiome while ensuring consistent and reproducible sampling conditions across all animals. Mice were housed in standardized conditions on Sani-Chips bedding (P.J. Murphy). Swab samples were snap frozen in liquid nitrogen and stored at −80˚C in 1.5 mL tubes until furth1er processing. Untargeted metabolomic profiling Metabolites were extracted as previously described [ 45 ]. Briefly, each swab was incubated in 50% LC-MS grade ethanol with internal standards (30 µM 4-nitrobenzoic acid, Sigma cat# 72910; 2 µM debrisoquine sulfate Sigma cat# D1306; 5 µM chlorpropamide Sigma cat# C1290 final concentrations) for 2 hours at 4 °C. Extracts were transferred to clean Eppendorf tubes, dried in a speed vac at room temperature, and resuspended in 50 µL of 0.1% formic acid in water. Samples were filtered (Bio-Inert® Membrane 0.2 µm, aqua Cat# ODM02C34) and transferred to 250 µl vials (Thermo fisher #C4011-13) for subsequent liquid chromatography (LC) time-of-flight MS analysis. A pooled quality control (QC) sample was prepared by combining 5 µL from each sample. Samples were run an LC-MS using a Waters Acquity Ultra Performance Liquid Chromatography (UPLC) with a BEH C18 1.7 µm, 2.1 × 100 mm column coupled to a Xevo® G2-S quadrupole time-of-ﬂight (QTOF) MS (Waters, Milford, MA, USA) with data independent acquisition (DIA). Positive and negative electrospray ionization (ESI+ and ESI–) was used with leucine enkephalin ([M + H]+ = 556.2771, [M-H]− = 554.2615) as lock-mass. Operating conditions for ESI were: capillary voltage 2.75 kV, cone voltage 30 V, desolvation temperature 500 ◦C, desolvation gas ﬂow 1000 L/Hr. Mobile phases were water with 0.1% formic acid (A) and ace
## Related Clinical Research

- [Standardized XRCT protocol for quantitative 3D shape-preferred orientation analysis in rocks](https://medichelpline.com/clinical-feed/plos-one-7-a-standardized-xrct-protocol-for-quantitative-3d-shape-preferred-orientation.md)
- [NHS launches world’s largest AI-assisted breast screening trial in England](https://medichelpline.com/clinical-feed/bmj-0-world-x2019-s-largest-ai-assisted-breast-screening-trial-begins-in-england.md)
- [Multimodal deep model integrates OCT and clinical text to detect age-related macular degeneration](https://medichelpline.com/clinical-feed/medrxiv-21-a-deep-multimodal-model-for-age-related-macular-degeneration-detection-using.md)
- [Boundary-sensitive, structure-adaptive lightweight network for CT liver segmentation](https://medichelpline.com/clinical-feed/plos-one-23-a-boundary-sensitive-and-structure-adaptive-lightweight-network-for-medical.md)
- [Automated aortoiliac calcification segmentation from arterial-phase CT: development and validation](https://medichelpline.com/clinical-feed/medrxiv-0-automated-aortoiliac-calcification-segmentation-from-arterial-phase-computed.md)

## Navigation
- [← Back to Radiology Feed](https://medichelpline.com/clinical-feed/radiology.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.