---
title: "Standardized XRCT protocol for quantitative 3D shape-preferred orientation analysis in rocks"
id: "plos-one-7-a-standardized-xrct-protocol-for-quantitative-3d-shape-preferred-orientation"
canonical_url: "https://medichelpline.com/clinical-feed/plos-one-7-a-standardized-xrct-protocol-for-quantitative-3d-shape-preferred-orientation"
content_type: "clinical_feed_article"
specialty: "Radiology"
source_name: "PLOS ONE (Medicine)"
source_url: "https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363434"
published_at: "2026-11-23T14:00:00.000Z"
evidence_level: "Journal Feed"
license: "CC-BY-NC-4.0 / Informational Use"
---
# Standardized XRCT protocol for quantitative 3D shape-preferred orientation analysis in rocks
## Provenance & Clinical Metadata
- **Canonical URL:** https://medichelpline.com/clinical-feed/plos-one-7-a-standardized-xrct-protocol-for-quantitative-3d-shape-preferred-orientation
- **Specialty:** [Radiology](https://medichelpline.com/clinical-feed/radiology.md)
- **Primary Source:** PLOS ONE (Medicine)
- **Source URL:** [Original Journal Publication](https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0363434)
- **Published At:** 2026-11-23T14:00:00.000Z
- **Evidence Rating:** Journal Feed
## Executive GIST (TL;DR)
- The authors present an end-to-end **XRCT** workflow that links acquisition, reconstruction, segmentation, grain extraction, fabric quantification, and oriented-section projection for rocks. - The workflow targets quantitative 3D measurement of mineral **shape-preferred orientation** (**SPO**) and emphasizes reproducible treatment of low-volume segmented objects that bias orientation estimates. - An expert-calibrated machine-learning classifier (ML-Threshold Selection) generates sample-specific candidate minimum grain-volume thresholds (**Vmin**)—reported as loose and strict candidates—for operator review before adopting an operating cutoff. - The classifier encodes seven object features: voxel-count (sample-specific volume) and six components of the symmetric log-ellipsoid tensor derived from per-object ellipsoid fitting. - Training used expert pseudo-labels; leave-one-sample-out cross-validation across five training samples produced held-out ROC AUC values reported between 0.906 and 0.996. - The protocol was demonstrated on spinel-bearing ultramafic rocks; spinel provides strong X-ray attenuation contrast and occurs as discrete objects suitable for segmentation. - For the example lherzolite xenolith (LE01), low-volume objects initially produced axis clustering aligned with scan axes; progressively applying the loose and strict **Vmin** candidates suppressed this voxel-grid aliasing and revealed the retained geological fabric. - Fabric quantification follows tensor averaging and uses corrected degree of anisotropy (P′) and shape factor (T). Bootstrap resampling (1,000 iterations) estimates confidence intervals for these metrics after filtering. - The workflow, all code, training data, per-grain datasets, and example volumes are openly archived on GitHub and Zenodo; the machine-learning code and trained model are provided. - Applicability is limited to phases with adequate attenuation contrast and discrete particle populations; the ML threshold model must be retrained for substantially different materials, and sensitivity to inter-operator variability has not been evaluated.
## Clinical Analysis & Structured Key Points
A standardized XRCT protocol for quantitative 3D shape preferred orientation analysis in rocks | PLOS One Browse Subject Areas ? Click through the PLOS taxonomy to find articles in your field. For more information about PLOS Subject Areas, click here . Article Authors Metrics Comments Media Coverage Peer Review Reader Comments Figures Figures Abstract Quantifying three-dimensional (3D) mineral shape-preferred orientation (SPO) is important for interpreting deformation, magma flow, sediment transport, and anisotropic rock properties. X-ray computed tomography (XRCT) enables non-destructive measurement of mineral SPO in three dimensions, but few openly documented workflows link data acquisition, image processing, object extraction, and fabric quantification. This Lab Protocol presents an end-to-end XRCT workflow covering data acquisition, volume reconstruction, phase segmentation, grain-parameter extraction, fabric quantification, and projection of the calculated fabric onto the physical sample for oriented sectioning. An expert-calibrated machine-learning procedure returns reproducible, sample-specific loose and strict candidate minimum grain-volume thresholds (Vmin) for review before an operating threshold is adopted. Filtering at the adopted threshold suppresses the low-volume, poorly resolved object population and associated geometric aliasing, improving the robustness of the calculated 3D SPO. The workflow is demonstrated for spinel-bearing ultramafic rocks; application to other systems requires separate calibration and evaluation. Citation: Li P, Chatzaras V, Foley M, Özaydın S, Rey P (2026) A standardized XRCT protocol for quantitative 3D shape preferred orientation analysis in rocks. PLoS One 21(11): e0363434. https://doi.org/10.1371/journal.pone.0363434 Editor: Benedetto Schiavo, National Autonomous University of Mexico Institute of Geophysics: Universidad Nacional Autonoma de Mexico Instituto de Geofisica, MEXICO Received: March 18, 2026; Accepted: November 9, 2026; Published: November 23, 2026 Copyright: © 2026 Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution License , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: The machine-learning code is openly archived at Zenodo ( https://doi.org/10.5281/zenodo.21678821) and on GitHub ( https://github.com/Puqing-Li/ML_Threshold_Selection) . The XRCT-derived per-grain datasets for the worked example and the five training samples, the processed fabric tables underlying the findings of this study, and the trained model are openly available in the same GitHub repository and permanently archived at Zenodo ( https://doi.org/10.5281/zenodo.21678821) . The LE01 raw projections, reconstructed and segmented XRCT volume, particle-analysis tables, and reconstruction metadata are deposited separately at Zenodo ( https://doi.org/10.5281/zenodo.21669376) . All other relevant data are available in the paper and its Supporting Information files. Funding: This research was supported by the Australian Government through the Australian Research Council’s Discovery Projects funding scheme (project DP220100709) and Linkage Projects funding scheme (project LP190100146), and by the European Union’s Seventh Framework Programme under REA grant agreement no. PIOF-GA-2012-329183. PL was supported by a China Scholarship Council (CSC) scholarship (202204910043). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Competing interests: The authors have declared that no competing interests exist. Introduction Mineral shape-preferred orientation (SPO) is a fundamental component of rock fabric, arising from the alignment of anisometric grains during deformation, magmatic, metamorphic, or sedimentary processes. Quantifying SPO provides critical insights into finite strain magnitude and geometry, deformation kinematics, polyphase deformation histories, and fluid transport within fault zones [ 1 – 9 ]. By resolving the angular relationship between mineral alignment and the flow plane, SPO analyses can constrain magma flow directions and pluton emplacement mechanisms [ 10 – 12 ], as well as inform paleocurrent reconstruction and the interpretation of soft sediment deformation features [ 13 – 15 ]. In addition, SPO exerts a strong control on the mechanical behavior and anisotropic physical properties of rocks, influencing seismic velocity [ 16 ], magnetic susceptibility [ 17 ], electrical conductivity [ 18 , 19 ], and permeability [ 20 ]. A quantitative understanding of SPO is therefore essential for linking microscale processes to the broader tectonic settings in which they operate. Traditional methods for quantifying three-dimensional (3D) SPO rely on measurements of grain shape and orientation from a series of differently oriented 2D sections through the rock volume, from which the fabric ellipsoid is reconstructed by combining the corresponding sectional ellipses (e.g., [ 1 , 21 – 23 ]). X-ray computed tomography (XRCT) has enabled non-destructive, 3D characterization of mineral SPO [ 24 – 27 ]. XRCT provides direct measurements of grain morphology, shape, orientation, and spatial distribution throughout whole rock volumes [ 25 , 26 , 28 – 30 ], enabling mineral shape fabrics to be quantified directly in three dimensions rather than reconstructed from combined 2D sections. XRCT-based fabric analysis comprises a sequence of processing steps, from acquisition and reconstruction to segmentation, filtering, and fabric quantification, whose outcomes depend on decisions made throughout the workflow. Several software packages support quantitative analysis of 3D XRCT datasets, including Morpho+ [ 27 ], TomoFab [ 24 ], Quant3D [ 25 ], and Blob3D [ 26 ], while machine-learning approaches are increasingly used for image segmentation [ 31 , 32 ]. However, treatment of low-volume segmented objects remains largely study-specific and is not usually implemented within a reproducible, end-to-end SPO-analysis workflow. This protocol presents a reproducible, step-by-step workflow for quantitative 3D SPO analysis in rocks using XRCT data ( Fig 1 ). It integrates data-acquisition optimization [ 33 , 34 ], mitigation of beam-hardening and ring artifacts [ 35 – 38 ], grain extraction, model-assisted generation of candidate minimum grain-volume thresholds (Vmin), and 3D fabric quantification [ 24 ] within a single openly documented workflow. A central focus is treatment of low-volume segmented objects. Near the spatial-resolution limit, voxel discretization can bias estimates of grain shape and orientation [ 33 , 34 ]. The protocol addresses this problem using expert-calibrated machine-learning predictions to generate reproducible, sample-specific candidate Vmin values; the adopted operating threshold is documented as part of the workflow. Download: PNG larger image TIFF original image Fig 1. Standardized XRCT workflow for quantitative 3D shape-preferred orientation analysis. https://doi.org/10.1371/journal.pone.0363434.g001 The workflow was developed to quantify the 3D rock fabric of spinel-bearing ultramafic rocks using the SPO of spinel grains. In these rocks, spinel forms a dense, discrete phase within lower-density silicate minerals (olivine, enstatite, and diopside). Applicability therefore depends on sufficient X-ray attenuation contrast and on the target phase occurring as discrete, resolvable objects. The workflow is not suitable for phases with weak contrast, interconnected networks that cannot be separated into individual objects, or particles represented by too few voxels for reliable shape characterization. The machine-learning thresholding procedure was developed and calibrated using spinel-bearing ultramafic rocks and should be retrained before application to substantially different particle populations. Because the candidate Vmin values are derived from expert-defined reference thresholds, the procedure is reproducible for a given model and dataset but remains dependent on expert calibration and geological interpretation. Sensitivity to inter-operator variability has not yet been evaluated. In this work, we focus on the data-cleaning component of the workflow (component 4 in Fig 1 ) and evaluate how sample-specific candidate Vmin values affect the calculated 3D fabric. Materials and methods The protocol described in this peer-reviewed article is published on protocols.io ( https://doi.org/10.17504/protocols.io.n92ld16znl5b/v4 ) and is included for printing as S1 File with this article. The analyzed samples are previously collected orogenic peridotites and mantle xenoliths spanning lherzolite and dunite lithologies, deformation from weakly deformed tectonites to mylonites, and several tectonic settings [ 8 , 29 , 30 ]. No new field sampling was undertaken, and no permits were required for the present study; sample provenance and contributions are documented in the code and data archive ( https://doi.org/10.5281/zenodo.21678821 ) and the Acknowledgments. Component-specific hardware requirements and approximate processing times are provided in the step-by-step protocol ( S1 File ). Reconstruction and segmentation are the most resource-intensive components, whereas model prediction and fabric-tensor calculation require no GPU and can be performed on a standard desktop. Expected results Protocol overview Fig 1 presents a visual summary of the workflow outlined in the protocol. The workflow consists of five major components: (1) XRCT scanning and acquisition of a stack of 2D radiographs; (2) reconstruction of the 2D radiographs into a 3D volumetric dataset that captures variations in X-ray attenuation; (3) image pre-processing, including artifact removal, visualization of the digital rock volume, segmentation of the mineral phase(s) of interest, and extraction of grain morphology and orientation parameters; (4) data cleaning and calculation of the fabric tensor; and (5) projection of the principal fabric planes onto the digital rock model and, ultimately, the physical sample. Although these five components are broadly applicable, some steps depend on the XRCT instrument and the software used for reconstruction and image pre-processing. Specifically, acquisition settings (component 1) depend on the scanner, whereas reconstruction (component 2) and artifact removal, segmentation, and extraction of grain parameters (component 3) depend on the software; the instrument, software, and settings used here are listed in the step-by-step protocol ( S1 File ). Rock composition, structure, size, and shape further influence acquisition settings, pre-processing, segmentation, and fabric-tensor calculation. The protocol documents the implementation used here rather than evaluating alternative approaches at each component. The following sections demonstrate this data-cleaning component on a representative sample and quantify its effect on the calculated fabric parameters. Case study We demonstrate the protocol using a lherzolite xenolith (sample LE01) from the Newer Volcanic Province in southeast Australia [ 39 ]. The xenolith comprises four main mineral phases: olivine, orthopyroxene, clinopyroxene, and spinel. In mantle xenoliths, shape fabric is commonly weak and is largely expressed by preferred orientation of pyroxene and spinel grains. XRCT is particularly effective for quantifying spinel SPO because spinel has strong X-ray attenuation contrast relative to the silicate matrix and generally occurs as discrete grains that can be segmented and analyzed individually [ 28 – 30 , 40 ]. The fabric-tensor calculation follows our previous work, based on 6D log-ellipsoid vectorization [ 41 ] and tensor averaging [ 42 ]. The present protocol documents the preceding XRCT, reconstruction, segmentation, and data-cleaning components and adds an expert-calibrated, model-assisted procedure for generating sample-specific candidate Vmin values. Identification of aliasing artifacts before Vmin filtering Following phase segmentation and removal of invalid records, the prefiltered LE01 dataset contains many low-volume objects. Before Vmin filtering, the effect of voxel discretization is expressed as artificial clustering of fitted ellipsoid axes parallel to the XRCT acquisition axes ( Fig 2a ), which weakens as low-volume objects are removed ( Fig 2b , c ). We therefore interpret this clustering as voxel-grid discretization rather than geological SPO. Objects represented by only a few voxels contain insufficient spatial information for stable ellipsoid fitting, consistent with established XRCT resolution limits [ 33 , 34 ]. In such objects, quantization can make the voxel-coordinate second-moment (covariance) matrix diagonal or near-diagonal, with zero or poorly constrained off-diagonal terms; the resulting fitted eigenvectors may then align with the X, Y, or Z voxel-grid axes, especially when eigenvalues are repeated or nearly repeated. Similar grayscale intensities prevent reliable removal by segmentation alone, so the prefiltered dataset provides the reference for evaluating volume filtering. Download: PNG larger image TIFF original image Fig 2. Principal ellipsoid axis orientations before and after Vmin filtering. Lower-hemisphere, equal-area stereographic projections show the maximum (Φ1, red), intermediate (Φ2, green), and minimum (Φ3, blue) principal ellipsoid axes. (a) Prefiltered input before Vmin filtering (n = 4,991); X, Y, and Z denote the XRCT acquisition axes. (b) Loose candidate (50 voxels; n = 2,212). (c) Strict candidate (154 voxels; n = 1,074). Contours show concentrations in multiples of uniform density (m.u.d.). Plots were constructed using TomoFab [ 24 ]. https://doi.org/10.1371/journal.pone.0363434.g002 Model-assisted minimum grain-volume threshold (Vmin) selection To mitigate geometric aliasing artifacts, we developed a supervised machine-learning classifier (ML-Threshold Selection) that returns reproducible, sample-specific candidate Vmin values. A fixed voxel-count cutoff is simple to apply but does not account for the relationships among object geometry, scan resolution, and the low-volume artifact population. The method encodes expert-selected physical-volume reference thresholds as training pseudo-labels. Using each sample's measured voxel size, the classifier estimates a below-threshold-class probability from object size, shape, and orientation. The loose and strict candidates are reviewed against the segmented volume, stereographic projections, and expected geological fabric before an operating point is adopted. The model represents each object using seven features: the object’s VoxelCount (physical volume divided by the sample-specific voxel volume) and the six independent components of the symmetric log-ellipsoid tensor derived from the fitted ellipsoid [ 41 ] (see also [ 30 ]). These features encode size, shape anisotropy, and orientation. A LightGBM gradient-boosted decision-tree classifier [ 43 ] was fitted to deterministic pseudo-labels derived from expert-selected physical-volume reference thresholds. Full feature definitions, model parameters, training details, cross-validation procedures, and implementation are provided in that archive; protocol Steps 52–55 summarize the operational workflow. Classification performance was assessed by leave-one-sample-out cross-validation across five training samples (35,745 objects); held-out ROC AUC values ranged from 0.906 to 0.996 ( S1 Fig ). A stratified five-fold split of pooled objects yielded an AUC of 0.989, but this is a non-independent diagnostic because objects from every sample entered both training and test folds. These metrics assess reproduction of expert-derived pseudo-labels, not independent physical artifact identity. The in-sample threshold comparison in S1 Fig is retained only as a consistency check. For each new sample, the fitted model produces a below-threshold-class probability for every object and calculates loose and strict candidate Vmin values from the retained-population mean-score curve ( Fig 3 ). The loose candidate follows the inflection point of the smoothed curve, whereas the strict candidate is the smallest retained volume above which no object exceeds the default 0.01 probability tolerance. These candidates are reproducible for a fixed model and input but are sensitivity bounds rather than physical ground truth; they are reviewed against the segmented volume, stereographic projections, and expected geological fabric before an operating threshold is adopted. The operating decision remains a single per-sample volume cutoff, rather than object-wise probability filtering, to preserve compatibility with standard fabric software and avoid shape- or orientation-selective removal. Full decision rules are provided in that archive; protocol Steps 52–55 summarize the operational workflow. Download: PNG larger image TIFF original image Fig 3. Below-threshold-class probability as a function of the volume threshold (Vmin). Each point is one segmented object, plotted by volume and below-threshold-class probability. The solid dark-red line is the mean probability among objects retained at each Vmin. Vertical dashed lines mark the loose (blue) and strict (orange) candidate thresholds, which bound a sensitivity interval for review before an operating threshold is adopted (LE01; n = 4,991 objects). https://doi.org/10.1371/journal.pone.0363434.g003 For LE01, low-volume objects dominate the prefiltered population and obscure the preferred orientations of better-resolved grains ( Fig 2a ). Applying the loose and strict candidates progressively suppresses scan-axis clustering ( Fig 2b , c ); the retained orientations are then evaluated as the geological fabric. 3D SPO quantification and uncertainty Filtering objects below the adopted minimum grain-volume threshold excludes objects that are too small for reliable shape and orientation measurements, resulting in a more robust estimate of the retained grain-shape fabric. We follow the tensor-averaging method of Brandon [ 42 ] to estimate the mean fabric tensor from the tensors describing the shape and orientation of individual spinel grains. We used the corrected degree of anisotropy ( P′ ) and the shape factor ( T ) to quantify the anisotropy and shape of the fabric ellipsoid [ 44 ]. The parameter P′ is given by: where f1, f2, and f3 are the natural logarithms of the normalized magnitudes of the maximum (V1), intermediate (V2), and minimum (V3) axes of the fabric ellipsoid (i.e., the magnitudes of the Φ1, Φ2, Φ3 principal axes), respectively, and f=(f1 + f2 + f3)/3. P′ varies from 1 (for a sphere, indicating no anisotropy) to infinity (with increasing ellipticity toward a line or plane). P′ is similar in mathematical formulation to the octahedral shear strain [ 45 ] used in Hsu plots [ 46 ]. The shape factor ( T ) is defined as: The value of T ranges from −1 (prolate) to +1 (oblate), with T = 0 corresponding to a plane strain ellipsoid. The parameter T is equivalent to the shape parameter commonly used to describe the magnetic fabric of rocks (anisotropy of magnetic susceptibility) [ 44 ], and is mathematically related to Lode’s parameter (Lode’s ratio) used to characterize the geometry of strain and grain aggregates in structural geology [ 46 ]. To evaluate statistical stability after filtering, the protocol employs bootstrap resampling [ 47 ]. For each of 1,000 iterations, n grains are sampled with replacement, where n is the number retained for that sample at the given threshold. The resulting P′ and T distributions provide summary statistics and 95% confidence intervals; Fig 4b , c shows the median and interquartile range, and S1 Table reports the corresponding confidence intervals. Download: PNG larger image TIFF original image Fig 4. Bootstrap analysis of fabric-parameter sen
## Related Clinical Research

- [NHS launches world’s largest AI-assisted breast screening trial in England](https://medichelpline.com/clinical-feed/bmj-0-world-x2019-s-largest-ai-assisted-breast-screening-trial-begins-in-england.md)
- [Multimodal deep model integrates OCT and clinical text to detect age-related macular degeneration](https://medichelpline.com/clinical-feed/medrxiv-21-a-deep-multimodal-model-for-age-related-macular-degeneration-detection-using.md)
- [Boundary-sensitive, structure-adaptive lightweight network for CT liver segmentation](https://medichelpline.com/clinical-feed/plos-one-23-a-boundary-sensitive-and-structure-adaptive-lightweight-network-for-medical.md)
- [Optimizing PALM imaging of the nuclear pore complex with mEos4b: oxygen and buffer effects](https://medichelpline.com/clinical-feed/biorxiv-2-optimizing-environmental-conditions-for-palm-imaging-of-the-nuclear-pore.md)
- [Automated aortoiliac calcification segmentation from arterial-phase CT: development and validation](https://medichelpline.com/clinical-feed/medrxiv-0-automated-aortoiliac-calcification-segmentation-from-arterial-phase-computed.md)

## Navigation
- [← Back to Radiology Feed](https://medichelpline.com/clinical-feed/radiology.md)
- [← All Clinical Specialties](https://medichelpline.com/clinical-feed.md)
## Medical & Regulatory Disclaimer

> [!CAUTION]
> MedicHelpline content is structured for research, educational, and professional discovery purposes. It does not constitute individual medical advice, clinical diagnosis, or treatment recommendations.
> Always verify dosing, contraindications, and regulatory alerts against official product labeling and primary regulatory sources before clinical decision-making.