Investigators reported a transient change in night-to-night variability of the REM-sleep fraction in the month before a first myocardial infarction (MI). The pattern was a decrease in variability at days 30–16 relative to each person’s baseline, followed by a return toward baseline over days 15–1. Data indicated that this decrease-then-return sequence was statistically uncommon when compared with 10,000 randomly placed index dates using a max-T approach (max-T p<0.001).
The observed components of the pattern were specific. The standard deviation (SD) of REM-fraction declined at days 30–16 (Cliff’s δ −0.30, p=0.004; OR per SD 0.53, 95% CI 0.35–0.80; max-T p=0.0034). Then, over days 15–1, RMSSD increased (δ +0.36, p<0.001; max-T p=0.0035). The authors noted that a day-by-day continuous decrease was not detected by cluster permutation testing (p=0.58), meaning the signal was a windowed transient rather than a steady linear trend.
The study team drew cases from the All of Us Research Program. Eligible adults had a first MI code and at least 180 valid Fitbit sleep nights in the 360 days preceding the index date. Cases (45) were matched to up to ten controls each (450 controls total) on sex, comorbidities, sleep apnea, calendar time and a propensity score. The primary cohort included all matched cases; a prespecified subgroup combined cases with diabetes and/or hypertension.
Analyses used each person’s baseline period (days 360–121) to quantify within-person change, then compared two prespecified pre-event windows (days 30–16 and days 15–1). The source reported adjustments for nightly heart rate, device wear and device type.
The main endpoints were the within-person change in night-to-night variability of the REM-sleep fraction measured with SD, RMSSD and coefficient of variation (CV). The statistical pipeline tested observed changes against a null distribution generated by 10,000 randomly placed index dates and allowed for choice of the pre-event window using max-T. This approach aimed to account for multiple window selection while preserving within-subject contrasts against baseline.
The principal signals were the SD decrease at days 30–16 and the RMSSD rise over days 15–1. The SD decrease contributed to discrimination between cases and controls when each person was scored against their own baseline; reported AUCs reached up to 0.66. The authors cautioned that this AUC estimate may be optimistic because the decrease in RMSSD attenuated in held-out halves of the matched sets during internal validation.
The study team applied the same analytic pipeline to several comparators. The SD decrease at days 30–16 was not seen at the same timing prior to admissions for pneumonia (69 cases), fracture or appendicitis (130 cases) or any-cause admissions (859 cases). Comparisons showed the SD decrease was larger before MI than before each of these other admission types (difference in δ −0.25 to −0.34).
Analyses that varied case definitions and inclusion criteria yielded consistent signals: the transient pattern persisted in the subgroup with diabetes and/or hypertension, in cases without recorded symptoms or treatment, when using the first angina code as the index date, and when people with heart failure were included. Adjustment for nightly heart rate, device wear and device type did not abolish the observed pattern, according to the authors.
Scoring each person’s pre-event windows against their individual baseline allowed case-control discrimination with AUCs up to 0.66. The authors reported that internal validation reduced some signal strength: the decrease in RMSSD was attenuated in held-out halves of the matched sets, suggesting that reported discrimination may be optimistic and that performance could fall in external data sets.
No trial of a prospective alerting strategy or clinical intervention was reported. The source did not provide details on how wearable sleep staging was validated against polysomnography in this cohort, nor did it give thresholds for alarm rules or clinical action.
The report carries several constraints the authors documented. It is a preprint and has not been peer-reviewed. The timing result is exploratory and the authors explicitly stated it requires confirmation in new cases. Participant-level data are not publicly shareable by the authors; authorised researchers can access All of Us data via the Researcher Workbench (Registered Tier Dataset v9). The paper noted competing-interest details related to a patent application but declared no other competing interests.
Unanswered questions recorded in the source include whether the timing and magnitude of the REM-variability signal generalize to other cohorts or to different wearable platforms, and whether a prospective monitoring strategy could achieve clinically useful predictive performance. The authors did not report prospective thresholds, device-specific calibration procedures, or polysomnographic validation within this manuscript. Confirmation in independent datasets and peer review remain the next concrete milestones identified by the study team.