The authors evaluated two semi‑automatic segmentation approaches to quantify condylar volume on CBCT in patients with unilateral overgrowth. They sampled ten adult patients who had undergone proportional condylectomy, and analyzed affected and non‑affected condyles from before and after surgery scans. A single blinded operator performed reproducibility testing twice with a one‑month washout, and reliability metrics were computed using the intraclass correlation coefficient (ICC) and Dahlberg random error calculations.
The team used a five‑step pipeline to create a reproducible condylar unit for volumetric measurement. First, thirteen 3D cephalometric landmarks were semi‑automatically generated with the ALI CBCT module and manually refined where needed. Next, head orientation was standardized using Frankfort horizontal, midsagittal, and transporionic planes. The mandible was semi‑automatically segmented with the AMASS module. The resulting segmentation was exported to ITK‑Snap for slice‑by‑slice refinement in axial, sagittal, and coronal views. The authors reported using open‑source tools—3D Slicer (v3.8) and ITK‑Snap (v3.8)—throughout this workflow.
This stepwise approach produced a consistent 3D condylar volume ready for comparison across timepoints and sides. The study team explicitly described each processing stage in the source and noted manual refinement when the automated prediction required correction.
Two anatomical cutoff landmarks defined the condylar segmentation boundaries. Method SN used the sigmoid notch as the reference plane. Method ML used the mandibular lingula instead. Both approaches were applied to the same anonymized CBCT datasets so that side‑to‑side and pre/postoperative volumes could be compared under consistent processing conditions.
The source reports that both methods are feasible to implement within the described semi‑automatic pipeline. Where automated landmarking required adjustment, the operator made manual corrections prior to final segmentation; the manuscript did not report additional alternative landmarks beyond SN and ML.
Data indicated excellent intra‑rater reliability for both segmentation methods. The investigators reported ICC values of 0.96 (95% CI 0.92–0.98) for method SN and 0.91 (95% CI 0.79–0.96) for method ML. Random measurement error calculated with the Dahlberg formula was higher for ML, and on average ML measurements were 9.9% higher on the second evaluation while SN measurements were 4.7% higher on retest.
These findings mean that both the sigmoid notch method and the mandibular lingula method produced reproducible volumetric estimates in this dataset, but SN showed slightly lower variability under a single‑operator assessment protocol.
The authors implemented semi‑automatic landmarking followed by manual refinement, which balances efficiency against the need for operator oversight when automated predictions deviate. The use of open‑source platforms (3D Slicer and ITK‑Snap) supports reproducibility across centers that can replicate the workflow. The source also noted potential segmentation challenges intrinsic to mandibular condyles on CBCT—adjacent glenoid fossa structures, the articular disc, and low bone density near the temporal region—which can complicate automated boundary definition and necessitate manual corrections.
Clinicians and researchers seeking to adopt volumetric condyle assessment should plan for a structured training and a standardized landmark protocol. The study provides an explicit five‑step procedure that can serve as a reference, but multi‑operator testing is needed to set inter‑rater thresholds and acceptable error margins for clinical decision making.
The source documents several constraints. The cohort comprised ten patients selected from a single private practice, which restricts external validity. All segmentations were performed by one blinded operator and repeated once after a four‑week interval; the study did not report inter‑rater reliability or multi‑center replication. The authors did not provide additional landmark alternatives beyond the two tested methods. Funding was not reported, and the study was retrospective with anonymized data collected between 20 May 2025 and 15 March 2026.
Unanswered questions recorded in the source include whether the slightly higher variability of method ML persists across multiple operators, how segmentation error scales with different CBCT machines or image quality, and what minimum detectable volume change should guide clinical management decisions after condylectomy. These items remain to be addressed in larger, multi‑operator studies that can define clinical thresholds and validate the two landmark strategies across diverse settings.