The study team enrolled subjects in Kampala between 2023 and 2025 and analyzed 316 participants, of whom 118 had microbiologically confirmed pulmonary tuberculosis and 198 did not. The investigators partitioned the cohort into training (n = 223), validation (n = 20), and a held-out test set (n = 73). The clinical-only classifier (random forest using routine variables) produced an area under the receiver operating characteristic curve (AUC) of 0.88 (95% CI, 0.80–0.95) on the test set. By contrast, the 12-zone ultrasound-only model yielded an AUC of 0.93 (0.86–0.97). When ultrasound images were combined with clinical variables, the 12-zone model reached an AUC of 0.95 (0.89–0.99). These results indicate higher internal discrimination for models that incorporated lung ultrasound image features alongside routine clinical data. The source did not report model calibration metrics in the test set beyond AUC and confidence intervals.
Investigators applied an attention-based multiple-instance learning network to one still frame from each of 12 predefined lung ultrasound zones per participant. The attention mechanism produced weights that the authors used to derive an abbreviated scanning protocol. From training-set attention weights the team selected six zones they considered most informative and retrained both ultrasound-only and combined models on those zones. On the held-out test set the 6-zone ultrasound-only model produced an AUC of 0.91 (0.83–0.97), while the 6-zone combined model achieved an AUC of 0.93 (0.86–0.99). The authors reported that the simplified protocol retained most of the discrimination seen with the full 12-zone scan. The source did not provide stepwise zone selection details beyond attribution to attention weights, nor did it report per-zone image characteristics or inter-operator acquisition variability statistics.
The study team evaluated operating points to assess screening utility. At a sensitivity fixed near 90%, the 12-zone combined model attained a specificity of 82.2% (95% CI, 34.9–97.8). The 6-zone combined model’s specificity point estimate at 90% sensitivity was 91.1% (95% CI, 25.0–98.0). The authors compared these point estimates against the 2025 World Health Organization minimum accuracy targets for a high-sensitivity screening test (≥90% sensitivity and ≥60% specificity) and reported that all 12-zone models and the 6-zone combined model met those thresholds by point estimate. Confidence intervals around specificity were wide; the source provided those intervals as reported above. The manuscript did not include decision-curve analyses or explicit threshold selection workflows beyond reporting the sensitivity-aligned specificities.
This was a prospective study that enrolled people aged 13 years or older with microbiologically confirmed pulmonary tuberculosis, household contacts, and symptomatic individuals with other respiratory diagnoses. One still image per zone (12 zones) formed the imaging dataset analyzed by the attention-based deep-learning pipeline. The source specifies participant counts and set allocations but did not supply additional acquisition protocol details such as ultrasound device models, operator training duration, or inter-rater agreement metrics. Ethical approvals came from the Mulago Hospital Research Ethics Committee (2349) and the Rutgers University Institutional Review Board (Pro2020003026). Adult participants provided written informed consent; adolescents aged 13–17 provided written assent plus parental or guardian consent. The authors declared no competing interests and committed to depositing data in a public repository upon publication, excluding participants who declined data sharing.
The authors acknowledged that these are internal performance estimates from a single-site prospective cohort and that external validation in intended-use screening populations is required. The study did not report external validation results, nor did it report implementation details such as operator training requirements, device heterogeneity, or real-world screening logistics. Confidence intervals for specificity at sensitivity-aligned operating points were broad, which limits precision in estimating real-world false-positive rates. Future work, as specified by the authors, must test the derived 6-zone protocol and combined-model performance in external cohorts representative of intended screening settings before deployment decisions can be made.