Twenty-eight critically ill neonates and infants, ages ranging from 2 days to 3 months, comprised the cohort. The investigators reported that 16 were boys and 12 were girls. Access for emergency peritoneal dialysis was achieved with a Tenckhoff catheter in eight patients and an adapted 12 Fr nasogastric tube in 20 patients. The study period spanned January 2022 to June 2023. The authors emphasized that in many resource-limited settings, pediatric PD catheters are not readily available, prompting use of adapted enteric tubes as an alternative for urgent peritoneal access.
The report did not include a full procedural protocol for tube adaptation, nor did it provide stepwise instructions for insertion technique in the abstract. Specific dialysis prescriptions — including dialysate composition, dwell volumes, cycle times or clinician criteria for switching access types — were not detailed in the source material provided.
The cohort showed rapid biochemical improvement after initiation of manual PD. Serum urea, creatinine and potassium all fell with statistical significance; the authors reported p < 0.001 for these reductions. Fluid status shifted markedly: within 72 hours the mean daily fluid balance moved from a positive +42.3 ± 14.8 mL/kg/day to a negative −12.4 ± 8.6 mL/kg/day. Those numbers indicate that clinicians achieved net fluid removal in the acute window following PD initiation.
Data indicated effective metabolic correction with manual exchanges. The study text did not supply individual patient trajectories or device-specific clearance metrics in the abstract, so detailed per-patient kinetics and dose–response relationships are not available from this source.
Investigators measured vasoactive support using the Vasoactive-Inotropic Score (VIS). Mean VIS fell from 40.4 ± 9.6 at baseline to 5.3 ± 3.1 after PD (p < 0.001). This large change in recorded vasoactive requirement accompanied the fluid and metabolic improvements described. The study team reported this as a signal of hemodynamic stabilization following correction of fluid overload and deranged biochemistry.
The abstract did not specify timing of repeated VIS measurements beyond the 72-hour window, nor did it describe other hemodynamic monitoring modalities employed.
Complication rates between the adapted nasogastric tube group and the Tenckhoff catheter group did not differ significantly, according to the authors. No cases of peritonitis were reported in the cohort. The abstract did not enumerate other specific complications by frequency (for example catheter malposition, leakage, exit-site infection, or mechanical obstruction), so readers must refer to the full manuscript for a granular safety breakdown.
All 28 patients recovered renal function, and there were no deaths reported in this retrospective series. Those outcome data apply to this cohort and timeframe; the authors cautioned that larger, prospective evaluation is necessary to establish reproducibility and safety more broadly.
Acute kidney injury followed three principal clinical scenarios in this group. Ten patients developed AKI after cardiac surgery with cardiopulmonary bypass (35.7%), 12 cases were associated with sepsis (42.9%), and 6 followed congenital pneumonia and complicated delivery (21.4%). The investigators framed peritoneal dialysis as the most practical renal replacement option for neonates and young infants when extracorporeal RRT is not feasible, especially in constrained-resource environments where catheter supply may be limited.
The authors argued that an adapted nasogastric tube can serve as a temporary peritoneal access option when standard pediatric PD catheters are unavailable; that claim was supported in this cohort by comparable complication rates and positive patient outcomes, as reported.
The authors acknowledged the study’s retrospective design and small sample size. They noted that prospective studies are needed to confirm safety and generalizability of using adapted nasogastric tubes for peritoneal access in neonates and infants. The abstract did not report on operator experience, standardized insertion technique, or long-term follow-up beyond recovery of renal function during hospitalization. Detailed dialysis parameters, infection surveillance protocols, and mechanical complication rates were not provided in the abstract and therefore remain unanswered by this source.
Clinicians and readers should interpret the findings in light of the study’s stated limitations and the fact that the report is a preprint that has not undergone peer review. The study team called for prospective evaluation to validate the feasibility and safety signals observed in this retrospective cohort.