This study compared relative signal intensity and tissue contrast of the choroid plexus (CP) across sequences, including double inversion recovery (DIR), fluid-attenuated inversion recovery (FLAIR), and T1-weighted (T1w) images both before and after contrast. DIR produced the highest CP signal intensity and the most consistent tissue contrast among all evaluated MRI sequences, with statistical significance reported at p < 0.001. The authors present DIR as a promising acquisition for enhancing CP visibility, especially in regions where conventional sequences under-represent CP tissue.
Manual segmentation reproducibility was assessed using intraclass correlation coefficients (ICCs). The intra-rater ICC for CP manual segmentations was 0.92, indicating robust within-rater consistency. The inter-rater ICC was 0.83, indicating strong agreement between raters. These reproducibility results supported the use of manual DIR-based masks as ground truth for training the automatic segmentation model.
The investigators trained a 3D nnU-Net on manually labeled DIR masks. The dataset consisted of 93 scans from healthy controls and individuals with multiple sclerosis, partitioned into a training set (n = 63), an internal test set (n = 20) and an external test set (n = 10).
Model performance against manual segmentation was reported using spatial overlap and volumetric error metrics. On the internal test set the nnU-Net achieved a Dice coefficient of 0.82. The model generalized to the external test set with a Dice of 0.75. The authors noted that performance was independent of scanner, clinical diagnosis, or absolute CP volume, suggesting robustness of the DIR-based approach across these variables.
The study compared the DIR-based nnU-Net and manual DIR segmentations with three publicly available segmentation tools designed for T1w or FLAIR images. DIR-based approaches yielded significantly larger CP volumes than all three public models (p < 0.01). Axial slice-wise volume distribution analysis showed a distinct bimodal profile in DIR segmentations. This bimodal distribution was attributed to better capture of CP within the temporal horn of the lateral ventricle; the difference versus T1w- and FLAIR-based models reached p < 0.001. Voxel-wise density maps also demonstrated spatial differences consistent with DIR capturing inferior and medial extents of the C-shaped plexus that conventional sequences and models tended to miss.
By harnessing the superior tissue contrast of DIR, the trained nnU-Net model achieved high segmentation accuracy and generalized across scanners and diagnostic groups in this cohort. The DIR-based method more fully delineated the inferior extent of the C-shaped CP, which was frequently under-segmented by T1w- and FLAIR-based approaches. These findings suggest that adopting DIR for CP imaging and segmentation may improve standardization of CP volumetry and increase reliability of CP measurements in studies of CNS disorders.
The authors emphasize that the work is a preprint and has not been peer reviewed; therefore the findings should not directly guide clinical practice until validated further.
The anonymized data supporting the study are available upon reasonable request. The segmentation model and associated code have been made publicly available at the project GitHub repository provided in the article.
Ethical approval was obtained from the Ethics Committee of the Technical University of Munich, School of Medicine and Health (reference number: 5848/13). The authors declare competing interests and funding sources in the manuscript: several authors reported fees or advisory roles with industry, and research funding declarations are listed. Specific competing interests and funder details were reported in the source.