iDose TR
TRAVOPROST INTRACAMERAL
Indications and usage 1 INDICATIONS AND USAGE iDose ® TR (travoprost intracameral implant) is indicated for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). iDose ® TR is a prostaglandin analog indicated for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT) ( 1 ) Dosage and administration 2 DOSAGE AND ADMINISTRATION For ophthalmic intracameral administration ( 2.1 ) The intracameral administration should be carried out under standard aseptic conditions ( 2.2 ) 2.1 General Dosing Information iDose TR is a travoprost delivery system consisting of a travoprost releasing implant pre-loaded in a sterile, single-dose inserter. iDose TR is administered intracamerally through a small, clear corneal incision and is anchored into the sclera at the iridocorneal angle. 2.2 Administration Instructions 1.
The procedure must be carried out under aseptic conditions which include use of sterile gloves and a sterile drape. 2.
Structured Monograph
Clinical summary
Indications and usage 1 INDICATIONS AND USAGE iDose ® TR (travoprost intracameral implant) is indicated for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). iDose ® TR is a prostaglandin analog indicated for the reduction of intraocular pressure (IOP) in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT) ( 1 ) Dosage and administration 2 DOSAGE AND ADMINISTRATION For ophthalmic intracameral administration ( 2.1 ) The intracameral administration should be carried out under standard aseptic conditions ( 2.2 ) 2.1 General Dosing Information iDose TR is a travoprost delivery system consisting of a travoprost releasing implant pre-loaded in a sterile, single-dose inserter. iDose TR is administered intracamerally through a small, clear corneal incision and is anchored into the sclera at the iridocorneal angle. 2.2 Administration Instructions 1. The procedure must be carried out under aseptic conditions which include use of sterile gloves and a sterile drape. 2. The eye should be anesthetized using general, retrobulbar, peribulbar, or topical anesthesia per standard operating room procedures. 3. The iDose TR implantation procedure must be performed under magnification that allows clear visualization of the anterior chamber angle and angle structures including trabecular meshwork, with the patient's head in a stabilized position. The pupil should not be dilated prior to the procedure. 4. An intracameral miotic can be injected to deepen the angle prior to insertion of the iDose TR. 5. It is recommended that the implant surgery be performed from the temporal side, using a temporal clear corneal incision. The implant will be implanted through the angle and the trabecular meshwork into the sclera on the nasal side. 6. Remove the barrier pouch from the carton and examine for damage. Open the barrier pouch, discard the oxygen scavenger packet, and remove the blister tray with Tyvek ® lid. Open the Tyvek lid containing the iDose TR pre-loaded inserter and present to the surgeon. The iDose TR implant and single-dose inserter should be handled in the sterile field. Caution: Do not use the iDose TR if the Tyvek lid has been opened or the packaging appears damaged. 7. Prepare for gonioscopy by turning the patient's head away from the surgeon by approximately 15° to 25° and tilt the scope toward the surgeon by approximately 35°. The total combined angle should be approximately 50° to 60°. 8. Place a small amount of viscoelastic on the cornea. Position the gonioprism on the cornea using light touch gonioscopy. Adjust the microscope to locate and focus on the trabecular meshwork. 9. Inspect the angle with a gonioprism to ensure that a good view of all angle structures is available at the nasal implant location. 10. Hold the single-dose inserter with your index finger comfortably on the implant release button (see Figure 1 ) Figure 1 11. Perform a detailed inspection of the tip of the sterile inserter under magnification to ensure that the iDose TR implant is present (see Figure 2 ). Figure 2 12. Create a clear corneal incision of approximately 2.4 mm at the temporal limbus location using an instrument of the surgeon's choice. 13. Add a cohesive viscoelastic to the anterior chamber as needed to form the anterior chamber and improve visualization of the angle. Be careful not to overinflate. 14. Insertion of the implant: a. When ready for implantation, remove the safety clip which holds the release button in place by squeezing and rocking the clip backwards (see Figure 2 ). Place finger on the release button to ensure it remains in the forward position and does not prematurely release the implant. b. To smoothly enter the anterior chamber, slide the inserter tip with implant "side to side" in the incision. c. Advance to the pupillary margin and ensure there is sufficient cohesive viscoelastic on the cornea before replacing the gonioprism onto the cornea. d. Take care to avoid contact with the lens or cornea. e. Advance to the anterior chamber angle and approach the trabecular meshwork (see Figure 3 ). Figure 3 f. Press the implant directly through the trabecular meshwork, compressing the tissue until the implant anchor securely penetrates the sclera through the back wall of Schlemm's canal. The base of the implant reservoir should be firmly in contact with and compressing the trabecular meshwork. g. Once the anchor of the implant is securely embedded in sclera, pause for the tissue to relax. Carefully slide the implant release button backwards to open the inserter tip with grasper and release the implant from the inserter (see Figure 4a ). Ensuring the implant has released from the inserter grasper, slowly remove the inserter straight back (see Figure 4b ). Avoid pulling the implant out of position. Figure 4a Figure 4b h. Apply slight pressure to the sides of the implant with the tip of the inserter to ensure the implant is fully anchored into sc
Monitoring
- • 5 WARNINGS AND PRECAUTIONS Iridocorneal Angles : iDose TR should be used with caution in patients with narrow angles or other angle abnormalities ( 5.1 ) Device Dislocation : Monitor patients routinely to confirm the location of the iDose TR at the site of administration ( 5.2 ) Pigmentation : Increased pigmentation of the iris can occur.
- • Iris pigmentation is likely to be permanent ( 5.8 ) 5.1 Iridocorneal Angles iDose TR should be used with caution in patients with narrow iridocorneal angles (Shaffer grade 65 years 1,600 (cells/mm 2 ) 1,120 (cells/mm 2 ) 5.5 Corneal Endothelial Cell Loss iDose TR should be readministered with caution in eyes with 10% or greater loss in central corneal endothelial cell density from pre-administration baseline (adjusted for age-related 1% loss per year and for a 10% loss following an anterior segment surgical procedure [e.g., cataract surgery]).
- • If baseline corneal endothelial cell density was not established prior to the initial administration of iDose TR and only a single eye is implanted, a 10% threshold level of endothelial cell density loss as a difference of the implanted eye versus un-implanted contralateral eye should be considered before readministering iDose TR.
- • 5.6 Macular Edema Macular edema, including cystoid macular edema, has been reported during treatment with ophthalmic travoprost, including iDose TR intracameral implant.
Interaction Notes
- • Review official label interaction section.