Optic nerve involvement is common in multiple sclerosis and is included among sites for dissemination in space in the latest McDonald criteria. Accurate MRI detection of optic nerve lesions is important for diagnosis and monitoring, but the optimal MRI sequence for routine follow-up remains unclear. This study set out to compare three MRI sequences—short tau inversion recovery (STIR), fat-suppressed FLAIR (fs-FLAIR), and double inversion recovery (DIR)—for their diagnostic performance in detecting optic nerve lesions in patients with established MS.
Fifty-nine patients with MS underwent MRI that included the three sequences of interest: STIR, fs-FLAIR, and DIR. In addition to the imaging, visual evoked potential (VEP) testing was performed to provide a functional correlate for optic nerve dysfunction. Lesion detection on each MRI sequence was assessed independently and then compared to structural and functional reference measures. The preprint reports that assessments were made across sequences and that comparisons to standards (structural and functional) were part of the analysis.
The sequences evaluated were:
The study examined whether the dedicated orbital sequence (STIR) provided superior detection of optic nerve lesions compared with whole-brain sequences (fs-FLAIR and DIR) in the follow-up setting.
Lesion detection results from each MRI sequence were compared against structural and functional standards. Functional assessment used VEP testing. The preprint indicates these comparisons were used to evaluate sensitivity to structural and functional changes, although detailed numeric performance metrics or specific cutoff criteria were not reported in the source abstract.
No significant differences were observed in optic nerve lesion detection among STIR, fs-FLAIR, and DIR.
All three sequences demonstrated similar sensitivity when compared to the structural and functional reference measures, including VEP findings.
The incremental diagnostic benefit of adding an orbital-specific sequence (STIR) to a whole-brain protocol (fs-FLAIR or DIR) was limited in the context of follow-up imaging for patients with established MS.
In this cohort of 59 patients with established MS, whole-brain sequences commonly used in routine brain MRI—fs-FLAIR and DIR—performed comparably to a dedicated orbital sequence (STIR) for detecting optic nerve lesions. The authors interpret these findings to support the feasibility of simplifying follow-up MRI protocols by omitting additional orbital sequences. Potential advantages of such an approach include reduced scan time and lower patient burden without apparent loss of diagnostic sensitivity for optic nerve lesions in the follow-up setting.
Clinicians and imaging teams considering protocol adjustments should weigh these findings against local imaging capabilities and clinical priorities. The preprint reports the overall conclusion but does not present full numeric performance details in the abstract; readers seeking metrics such as sensitivity, specificity, or lesion-level concordance should consult the full manuscript or contact the authors for the data.
Ethical approval for the study was granted by the Medical Research Council National Scientific and Ethical Committee (ETT TUKEB) of the National Institute of Pharmacy and Nutrition (approval number reported in the source). The authors state that patient consent procedures were followed and that necessary approvals were obtained. The preprint declares no competing interests. The authors indicate that data from the study are available on reasonable request.
Notes on reporting
This summary is based on the medRxiv preprint abstract and associated metadata. The posted preprint date and additional study details are available from the source; specific numeric performance measures and fuller methodological descriptions were not reported in the abstract and would require consultation of the full preprint or direct contact with the authors for comprehensive appraisal.