Diffusion-weighted MRI extends beyond the conventional diffusion tensor approach to interrogate tissue microstructure in vivo, offering the potential to characterise cellular architecture noninvasively. Despite this promise, clinical adoption has been constrained by three main barriers: the complexity of diffusion sequence design, lengthy acquisition protocols, and the challenge of reliably estimating high-dimensional microstructural model parameters from clinical-quality data. The authors frame the work as addressing these practical obstacles to make advanced microstructural imaging feasible in routine clinical workflows.
The study introduces a combined approach that pairs optimised diffusion encoding with modern simulation-based inference. The encoding was selected to capture time-dependent diffusion effects and to support multi-compartment modelling while remaining compatible with clinical scanner constraints. Simulation-based inference — implemented via neural-network–based tools for training and parameter estimation — is used to robustly estimate microstructural model parameters from the acquired diffusion signals. Together, these elements aim to reduce required acquisition time and improve the stability of parameter recovery compared with traditional high-dimensional fitting techniques.
Validation of the proposed framework followed two complementary paths. First, in-depth in silico experiments explored the parameter recovery performance of the combined encoding and inference pipeline under controlled conditions, assessing robustness across simulated noise levels and model parameter ranges. Second, in vivo validation used both human and rodent MRI data to demonstrate performance in biological systems. The in vivo evaluation included publicly available datasets previously reported in the literature as well as newly acquired human scans; newly acquired datasets were not yet publicly available at submission but will be released on publication.
The framework produces a set of microstructural metrics derived from multi-compartment diffusion modelling. According to the preprint, these metrics are robust and reproducible across healthy individuals in the in vivo experiments. Additionally, the spatial distributions of the derived metrics were found to have significant associations with brain-wide expression patterns of cell-specific genes, suggesting biological plausibility and potential links to cellular composition. The manuscript reports these spatial associations as evidence that the metrics reflect underlying cellular architecture rather than purely imaging artefacts.
A central claim of the work is clinical feasibility: the optimized acquisition protocol requires less than 10 minutes of scanner time. This shorter protocol is intended to lower practical barriers for implementation in clinical settings and for use in diagnostic, stratification, or monitoring contexts. The authors emphasise that reducing acquisition time, combined with robust inference methods, is a prerequisite for broader clinical evaluation of advanced microstructural imaging techniques.
The authors state that the code for neural network training, model fitting, and inference is publicly available on GitHub. The study made use of publicly available animal and human MRI data from a prior publication (Garcia-Hernandez et al., 2022). At the time of submission, newly acquired datasets are not yet publicly available but will be released upon publication. Supplementary materials and links to data and code are provided in the preprint.
The research was conducted in accordance with the Declaration of Helsinki and received ethical approval from the Israeli Ministry of Health (approval number reported) and the Sheba Medical Center Ethics Committee (approval number reported). Written informed consent was obtained from all participants prior to participation. The authors confirm compliance with relevant ethical guidelines and reporting standards.
Funding sources declared in the preprint include grants from Fundacion La Caixa, the TELEM Program, the Spanish Ministerio de Ciencia e Innovación, Programs for Centres of Excellence in R&D Severo Ochoa, Generalitat Valenciana, and the Pasqual Maragall Foundation among others. The authors declared no competing interests.
As a medRxiv preprint, the study has not undergone peer review; the authors note that the findings should not be used to guide clinical practice at this stage. The manuscript reports validation in controlled simulations and in vivo in both humans and rodents, but details about population size, specific statistical values, and full quantitative results are contained in the full text and supplementary materials rather than the abstract. Newly acquired datasets were not yet publicly accessible at submission but are intended for release upon publication, which will facilitate external replication and further validation.
The authors present a time-dependent diffusion MRI framework that combines optimized diffusion encoding and simulation-based inference to enable multi-compartment microstructural modelling within clinically feasible scan times. They report robust, reproducible microstructural metrics that spatially correlate with cell-specific gene expression patterns and claim an acquisition time under 10 minutes. Code and links to data sources are provided to support reproducibility, and ethical approvals and funding sources are declared. Because the article is a preprint, further peer-reviewed evaluation is required before clinical adoption or application.