Investigators reviewed 9,236 medical records at the Universidade Estadual de Campinas to identify women who had a levonorgestrel 52-mg IUD inserted between 2007 and 2015 and who continued use without replacement for as long as 10 years. The cohort that met the study criteria numbered 669 users who continued beyond eight years; 502 completed year 9 and 327 reached year 10 with the device in place. Mean age at insertion was 33.2 ± 6.9 years, and mean age at the last follow-up visit was 43.7 ± 6.9 years. The authors reported age ranges (14–46 at insertion and 25–59 at last follow-up). These details were drawn directly from chart review; the source did not report randomization or protocolized prospective follow-up procedures.
Chart review was the study’s design. That design enabled a large historical sample to be assessed for extended-duration outcomes, but it also limited the data to what had been recorded in routine clinical practice. The article did not report additional stratified baseline characteristics beyond age in the abstract, and the record review method meant some event detail depended on documentation completeness in the source files.
The study team observed one accidental pregnancy at month 111 of use among the cohort followed to extended durations. That single pregnancy was the only pregnancy event reported in the dataset for users continuing up to 10 years. On this basis the authors reported sustained contraceptive effectiveness through the extended interval. Short sentence. The underlying data support a low pregnancy incidence in this retrospective sample, but the article did not provide additional pregnancy-rate calculations or person-years denominators in the abstract.
The single pregnancy outcome was explicitly mentioned; the source did not report whether that pregnancy resulted in continuation or removal of the IUD, nor did it specify management details for that case. There was no mention of comparative failure rates versus standard-duration use within the abstract, and no prospective efficacy endpoints were reported in this summary.
Investigators analyzed reasons for device discontinuation using predefined categories: accidental pregnancy, bleeding and/or pain, expulsion, medical indications, expiration of the approved duration, personal reasons, and menopause. The most common reason cited was participant-requested removal at the end of the approved duration. The authors therefore identified user choice at approved expiry as the leading cause of exit from device use in the dataset.
Bleeding patterns were reported at the 10-year milestone. About 30% of users reported amenorrhea at year 10 and roughly 30% reported regular bleeding; the remainder had other bleeding profiles. Short declarative sentence. The article’s abstract provides those proportions but does not present finer-grained longitudinal bleeding trajectories, daily bleeding diaries, or standardized bleeding-score measures in the abstract text. Nor did the abstract list detailed adverse-event frequencies beyond the discontinuation categories described.
Providers reading these results should note the practical pattern described: a substantial fraction of long-term users were amenorrheic at year 10, while a comparable fraction maintained regular bleeding. That balance framed the authors’ statement that the bleeding profile was favorable in extended use, based on the documentation available in the retrospective cohort.
The authors concluded that continuous use of the levonorgestrel 52-mg IUD for up to 10 years was associated with high contraceptive effectiveness, high continuation, and a favorable bleeding profile. Short statement. They also called for prospective studies to confirm efficacy and safety of extended use beyond the currently approved duration. The abstract explicitly states that prospective confirmation is needed; the retrospective nature of this review underlies that recommendation.
Limitations were inherent to the design: reliance on existing medical records, absence of randomized allocation, and limited reporting in the abstract of detailed adverse-event rates, person-time denominators, or management specifics for the single pregnancy event. The source did not report granular methodological items such as loss-to-follow-up rates, statistical calculations for pregnancy incidence, or standardized bleeding-assessment tools within the abstract text. These gaps constrain how directly the dataset can inform guideline changes or regulatory extension decisions.
The study provides retrospective, chart-based evidence that extended continuous use may maintain low pregnancy incidence and acceptable bleeding patterns in a Brazilian clinical population, but the authors did not claim definitive proof. Prospective trials with predefined endpoints, standardized bleeding assessments, and complete safety reporting were recommended by the study team as the next step.